Datasheet
32
40
50
63
80
100
D-A73
D-A80
D-A79W
D-A9
D-A9V
D-M9
D-M9V
D-M9W
D-M9
WV
D-M9
AL
D-M9AVL
A
8
11.5
9.5
12
15
18
B
3.5
6.5
9.5
12.5
17
23.5
A
12.5
16
13.5
16
19
22
B
7.5
10.5
14
17
21.5
28
D-F7NTL
A
20.5
24
21.5
24
27
30
B
15.5
18.5
22
25
29.5
36
A
15.5
19
16.5
19
22
25
B
10.5
13.5
17
20
24.5
31
A
15
18.5
16
18.5
21.5
24.5
B
10
13
16.5
19.5
24
30.5
A
18
21.5
19
21.5
24.5
27.5
B
13
16
19.5
22.5
27
33.5
A
14
17.5
15
17.5
20.5
23.5
B
9
12
15.5
18.5
23
29.5
D-P3DW
(mm)
Bore size
Auto switch
model
D-A72/A7
H/A80H
D-A73C/A80C/F7
D-F79F/J79/F7
V
D-J79C/F7
W
D-J79W/F7
WV
D-F7BAVL/F7BAL
12
16
20
25
32
40
50
63
80
100
U
21.5
22.5
25.5
28
36
38
43.5
48.5
57
65.5
U
23.5
24.5
27.5
30.5
36.5
40
45
50.5
59
67
U
26.5
27.5
30
32.5
39.5
42.5
48
53.5
61.5
70
U
21
22
24.5
27.5
34
37.5
43
48
56.5
64.5
U
27.5
28.5
31
34
40.5
43.5
49
54.5
62.5
71
U
24.5
25.5
28
31
37.5
40.5
46
51.5
59.5
68
U
21.5
22.5
25
28
30
32
37.5
42.5
51
59
U
19
20
23
26
27.5
30
35
40.5
49
57
D-F7
/J79
D-F7
W/J79W
D-F7BAL
D-F79F/F7NTL
D-A7
H/A80H
D-F7V
D-F7WV
D-J79C
D-A7
D-A80
D-A73C
D-A80C
D-A79WD-M9
VD-A9V
(mm)
D-P3DW
U
—
—
—
—
33
36.5
42
47
55.5
65.5
Bore size
Auto switch
model
∗ The applicable auto switches for the CDQ2
R/
V (water resistant) are the D-M9
A(V)L type.
∗ The D-P3DW
type is available from ø32 to ø100.
Auto switch
model
D-M9AL
D-M9AVL
D-F7BAL
D-F7BAVL
20
25
32
40
50
63
80
100
19
19.5
22
16
14
16.5
19.5
24
A
7.5
8
9
11.5
14.5
17.5
22
27
B
18
18
19.5
13.5
11.5
14
17
21.5
A
6.5
7
6.5
9
12
15
19.5
24.5
B
Applicable Cylinder Series:
CDQ2R/V (Water resistant
)
Bore size
(mm)
(mm)
Auto switch
model
125
140
160
180
200
69.5
76.5
85.5
105.5
112.5
D-M9V
D-M9WV
D-M9AVL
U
67.5
74.5
83.5
103.5
110.5
D-A9V
U
75.5
82.5
91.5
—
—
D-A7
D-A80
U
76.5
83.5
92.5
—
—
D-A7H/A80H
D-F7/J79
D-F7W/J79W
D-F7BAL
D-F79F/F7NTL
U
82.5
89.5
98.5
—
—
D-A73C
D-A80C
U
79
86
95
—
—
D-F7V
D-F7WV
D-F7BAVL
U
81
88
97
—
—
D-J79C
U
78
85
94
—
—
D-A79W
U
Bore size
Applicable Cylinder Series: CDQ2S (Anti-lateral load)
Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
Auto Switch Mounting Height
Applicable Cylinder Series: CDQ2, CDQ2W, CDQ2-S/-T (Single acting), CDQ2K, CDQ2KW
(Non-rotating rod), CDQ2 (Long stroke), CDQ2S (Anti-lateral load),
CDQ2R/V (Water resistant)
Applicable Cylinder Series: CDQ2, CDQ2W (Large bore size)
Standard
Large Bore
Size
Long Stroke
Non-rotating
Rod
Axial Piping
Anti-lateral
Load
With End Lock
Water
Resistant
Auto Switch
With Auto
Switch
Made to Order
Series CDQ2Compact Cylinder
196