Datasheet

Auto switch (Sensor section)
Auto switch (Sensor section)
Auto switch (Amplifier section)
Auto switch (Amplifier section)
Indicator light
Indicator light
Lead wire length D-F7NJL: 3 m
D-F7NJZ: 5 m
Lead wire length D-F7NJL: 3 m
D-F7NJZ: 5 m
Lead wire length: 3 m
Lead wire length: 3 m
15 20 25 30 35 40 45 50 70 100
16
20
25
32
40
50
63
ø16 to ø25
Bore size
(mm)
16
20
25
32
40
50
63
A
8
8
8
9.5
13.5
11.5
14
B
5.5
7
7.5
6.5
9
12
15
U
23.5
25.5
28.5
32.5
36
42
48.5
(mm)
ø32 to ø63
D-F7NJL(Z)
16 20
BQ-1
25 32 40
BQJ1-032
50 63
Weight (g)
1.5
8.5
BQ-1
BQJ1-032
U
22
11
21.6
21.6
A
A
B
B
64.5
64.5
4
4
22
22
U
22
11
Heat resistant compact cylinder CDQ2 series (ø16 to ø63), which can mount heat resistant solid state switch. (D-F7NJ , Max. 150°C)
XB14F7NJL
Cylinder with heat resistant auto switch
Standard model no.
How to Order
CDQ2
Symbol
Cylinder with Heat Resistant Auto Switch
-XB14
Applicable Series
Series
CQ2
CQ2
Standard
Model Action
Double acting, Single rod
Applicable to ø16 to ø63
Except with rubber bumper
Body shape: Same as the existing product
Note
L
Z
Specifications
Applicable cylinder
Series
Bore size (mm)
Type
Fluid
Proof pressure
Maximum operating pressure
Minimum operating pressure
Ambient and fluid temperature
Rubber bumper
Rod end thread
Stroke length tolerance
Piston speed
Compact cylinder/Standard
CQ2
16, 20, 25, 32, 40, 50, 63
Non-lube
Air
1.5 MPa
1.0 MPa
0.05 MPa (0.07 MPa: for ø16 only)
0 to 150°C
None
Male or female thread
50 to 500 mm/s
+1.0
0
mm
Note) Refer to page 1319 in Best Pneumatics No. 2 for further information on auto switches.
Standard stroke (mm)
• Manufacture of intermediate strokes
Intermediate strokes in 1 mm intervals are available by installing
a spacer in the standard stroke cylinder.
Bore
size
(mm)
Auto Switch Proper Mounting Position (Detection at Stroke End)
The dimensions on the cylinder body is equivalent to the standard, double acting, single rod of the CDQ2 series.
Note 1) Auto switches are shipped in the same package, but not assembled in order to protect it at the time of shipment. Assemble it by referring to A, B
dimensions for mounting position shown in the above table.
Note 2) The tightening torque of the auto switch mounting M3 screw must be 0.5 to 0.7 N·m.
Auto Switch Mounting Bracket/Part No.
Auto switch
model
Bore size (mm)
Auto Switch Mounting Bracket/Weight
Mounting bracket part no.
Note) The body shape is the same as the existing product.
“Z” is not included in the model number.
Series CQ2Made to Order
213