Datasheet
Model
Type
Mounting
Operating system
Operation mode
Reset system
Display system
Number of digits
Memory holding {Storage medium}
Input signal type
Count input
Pulse signal system
Counting speed
Control signal input
Sensor power supply
Output signal type
Preset output configuration
Output type
Output delay time
Communication system
Output transistor mode
Power supply voltage
Power consumption
Withstand voltage
Insulation resistance
Ambient temperature
Ambient humidity
Noise resistance
Shock resistance
Impact resistance
Weight
CEU5 CEU5-D CEU5P CEU5P-D CEU5B CEU5B-D CEU5PB CEU5PB-D
Multi-counter
Surface mounting (DIN rail or Screw stop)
Adding - subtracting type
Operating mode, Data setting mode, Function setting mode
External reset terminal
LCD (With back light)
6 digits
Setting value (always held), Count value (Hold/Non-hold switching), {E
2
ROM (Warning display after writing approx. 800,000 times: E2FUL)}
Count input, Control signal input (Reset, Hold, Bank selection)
No-voltage pulse input
90° phase difference input
∗
1
/ UP/DOWN separate input
∗2
100 kHz
∗
1
Voltage input (12 VDC or 24 VDC)
10.8 to 13.2 VDC, 60 mA
Compare/Hold/One-shot (100 ms fixed pulse)
Separate 5 point output/Binary code output
5 ms or less (for normal output)
RS-232C
NPN open collector
Max 30 VDC, 50 mA
NPN open collector
Max 30 VDC, 50 mA
∗
3
PNP open collector
Max 30 VDC, 50 mA
PNP open collector
Max 30 VDC, 50 mA
∗
3
90 to 264 VAC
20 VA or less
21.6 to 26.4 VDC
10 W or less
90 to 264 VAC
20 VA or less
21.6 to 26.4 VDC
10 W or less
90 to 264 VAC
20 VA or less
21.6 to 26.4 VDC
10 W or less
90 to 264 VAC
20 VA or less
21.6 to 26.4 VDC
10 W or less
0 to 50°C (No freezing)
35 to 85% RH (No condensation)
Square wave noise from a noise simulator (pulse duration 1 µs) between power supply terminals ±2000 V, I/O line ±600 V
Endurance 10 to 55 Hz; Amplitude 0.75 mm; X, Y, Z for 2 hours each
Endurance 10 G; X, Y, Z directions, 3 times each
350 g or less
∗1) 90° phase difference input
∗ 3) 15 mA when BCD is output.
A:
B:
C:
D:
t : 10 µsec or more required
Counting input pulse duration
Counting speed f = = = 100000 Hz
∗ 2) UP/DOWN input
Input wave form conditions: At a maximum of 100 kHz,
the UP/DOWN wave form should be as shown below.
Between case and AC line: 1500 VAC for 1 min.
Between case and signal ground: 500 VAC for 1 min.
Between case and AC line: 500 VDC, 50 MΩ or more
Preset output, Cylinder stop output, BCD output
Preset output, Cylinder stop output
Multi-counter/Specifications
Multi-counter/Dimensions
MULTI COUNTER: CEU5
A
COM
COM COM
B
12 VDC
GND F.G.
R.S.
HOLD
BANK1 BANK2
COM
S.STOP
OUT1OUT2OUT3
OUT4
OUT5
100 to 240 VAC
COUNT
PRESET
FUNC.
SD
SG
RD
RS-232C
UP
LEFT
RIGHT
DOWN
SEL.
SET
MODE
104
10
7
24-M3 x 0.5
4-ø4.5
BCD output connector
33.5
113±0.2
125
59
64
56
35.5
(DIN rail mounting)
68 ±0.2
804
A
I
J
A phase
B phase
B
t
CD
5 µsec
5 µsec
5 µsec
+12 V
±10%
UP
pulse
+12 V
±10%
DOWN
pulse
2.5 µsec or more required
1
t
1
10 x 10
–6
≅ 100 kHz
Series CEU5
10-12-28