Datasheet

H2
MK
ML + Adjustment
øMI
ZZ + 2 x Stroke + Adjustment (A: 25 mm, B: 50 mm)
MH + Stroke + Adjustment
Stroke
MT
S
+ Stroke
Stopper
Stopper bracket
Width across flats B2
MM2
Width across flats MA
Symbol
H2
MK
ML + Adjustment
ZZ + 2 x Stroke + Adjustment (A: 25 mm, B: 50 mm)
MH + Stroke + Adjustment
øMI
StrokeMT
S
+ Stroke
MM2
Width across flats B2
Width across flats MA
Adjustable range
Series CG1
-XC8
Symbol
7
Adjustable Stroke Cylinder/Adjustable Extension Type
It adjusts the extending stroke by the stroke adjustable mechanism equipped in the head side.
Applicable Series
Series Description Model Action Note
CG1-Z
Standard type
CG1
Double acting Except with air cushion
Non-rotating rod type
CG1K
Double acting Except with air cushion
Direct mount type
CG1R
Double acting Except with air cushion
On the axial foot type, the foot is wedged and bolted between the
cylinder and the stopper bracket at the time of shipment. On other
types, it is placed in the same package, (but not assembled).
[mm]
Bore
size
B2 H2 MA MH MI MK ML MM2 MT S ZZ
20
10 3.6 12 38 14 7 18 M6 x 1 9 77 150
25
13 5 17 41 20 9 18 M8 x 1.25 11 77 158
32
13 5 17 41 20 9 18 M8 x 1.25 11 79 160
40
17 6 1947251024
M10
x
1.25
11 87 184
50
19 8 24 60 32 13 32 M14 x 1.5 11 102 220
63
19 8 24 60 32 13 32 M14 x 1.5 13 102 220
Series CG1K/CG1R
Specifi cations
Stroke adjustment symbol A B
Stroke adjustment range [mm] 0 to 25 0 to 50
Additional specifi cations Same as standard type
How to Order
Bore
size
B2 H2 MA MH MI MK ML MM2 MT S ZZ
20
10 3.6 12 38 14 7 18 M6 x 1 9 83 148
25
13 5 17 41 20 9 18 M8 x 1.25 11 85 158
32
13 5 17 41 20 9 18 M8 x 1.25 11 91 164
40
17 6 1947251024
M10
x
1.25
11 103 189
50
19 8 24 60 32 13 32 M14 x 1.5 11 120 225
63
19 8 24 60 32 13 32 M14 x 1.5 13 126 231
[mm]
Precautions
1.
When the cylinder is operating, if something gets caught between the
stopper bracket for adjusting the stroke and the cylinder body, it could
cause bodily injury or damage the peripheral equipment. Therefore, take
preventive measures as necessary, such as installing a protective cover.
2. To adjust the stroke, make sure to secure the wrench flats of the
stopper bracket by a wrench etc. before loosening the lock nut. If the
lock nut is loosened without securing the stopper bracket, be aware that
the area that joins the load to the piston rod or the area in which the
piston rod is joined with the load side and the stopper bracket side
could loosen fi rst. It may cause an accident or malfunction.
Warning
Adjustable stroke cylinder/adjustable extension type
StrokeBore sizeMounting style Type Stroke adjustment symbol
XC8CG1 Z
Except clevis type
Dimensions
(Dimensions other than below are the same as standard type.)
55
Series CG1