IDX-OM-H006-I Initial issue: January 2004 9th edition : November 2011 Operation Manual PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF1E-10 IDF2E-10 IDF3E-10 IDF3E-20 IDF4E-10 IDF4E-20 IDF6E-10 IDF6E-20 IDF8E-10 IDF8E-20 IDF11E-10 IDF11E-20 IDF15E-10 IDF15E-20 Please read this manual prior of using the air dryer. Keep the manual readily available for reference. © 2016 SMC CORPORATION All Rights Reserved.
To Customers Thanks for purchasing SMC Refrigerated Air Dryer. This opertion manual must be read and understood throughoutly before handling. It provides all essential information for maximizing product operating efficiency, as well as, for safe and longer life span operation. For safety operation of SMC Refrigerated Air Dryer, read thoroughly and follow stated safety instructions, as well *1 *2 as regulation stated within ISO 4414 & JIS B 8370 .
Table of Contents Table of Contents To Customers Chapter i Safety Instructions i-1 Warning: Before Using Air Dryer.........................................................i - 1 i-1-1 i-2 i-2-1 i-2-2 i-2-3 i-2-4 i-2-5 i-2-6 i-2-7 i-2-8 i-2-9 Meanings of signs: Caution, Warning, Danger..............................................i - 1 Danger Classifications / Position of Danger warning label ......i - 3 Danger Classifications ................................................................................
i Safety Instructions i Safety Instructions Before use, read and comprehend important cautionary notification well on this operattion manual. i–1 Warning: Before Useing Air Dryer In this chapter, the stated contents are especially about safety way to use the product. for customer. An Air Dryer is installed on the downstream of the air compressor to remove moisture. We, manufacturer, cannot take any responsibility if you use it for any other purpose.
i Safety Instructions Warning Statements with the “Danger” sign explain about possibilities that can result in serious injury or loss of life if someone handle wrongly during operation or maintenance and did not follow the procedure to avoid danger. Caution Statements with the “Danger” sign explain about possibilities that can result in injury or product damage if someone handles wrongly during operation or maintenance and did not follow the procedure to avoid danger.
i Safety Instructions i–2 Danger Classifications / Position of Danger Warning Label To protect operator’s sefety, we group danger into some types uniquely and attached labels indicating those types. Comfirm the contents of the danger types and positions of the labels before operation. Warning No one but professionals should operate an air dryer. Transportation, installation, and maintenance involve risks.
i Safety Instructions i – 2 – 2 Danger of Electricity Inside of this product, there is power-supplying section with high voltage separated by the cover panel. Do not operate the product without the cover panel. No one but trained qualified person should operate or inspect in the power transmission sections. Warning Read with caution and pay attention to the notations on danger warning labels. Do not remove or rub danger warning labels. Confirm the positions of danger warning labels.
i Safety Instructions i–2–6 Positions of Danger Warning Label Warning Read with caution and pay attention to the notations of danger warning labels. Do not remove or rub danger warning labels. Confirm the positions of danger warning labels. ! ! WARNING 警告 1 Remove panels for maintenance only. 2 Never insert anything into product to ensure safety. 3 Cut power prior to maintenance to prevent electric shock. 4 Settle product to room temp.before maintenance toprevent burn or frostbite.
i Safety Instructions i–2–7 Danger of Refrigerant Caution This product uses Fluorocarbon (HFC) as a refrigerant. This product is specified by “Class 1 Fluorocarbon Collection and Destruction Law in Japan.” It is strictly forbitten to emit Fluorocarbon to the atmosphere. Before you repair this product, you should collect the refrigerant with “Refrigerant collector.” Then, ask a destruction agency to dispose of collected refrigerant.
i Safety Instructions i – 2 – 8 Cautions about Usage Warning Read with caution and pay attention to the notations on danger warning labels. Do not remove or rub danger warning labels. Cimfirm the positions of danger warning labels. ! CAUTION 注 意 1 Read manual before operation. 2 Ensure vantilation and maintenance space. 3 Keep water away from the product. 4 Secure In / Out connector with spanner during piping. 5 Wait 3 minutes before restart. 6 Ensure Running Condition / Evaporating Tem p.
i Safety Instructions i–3 Disposal When you dispose of the product, you shoud collect the refrigerant and the refrigerat oil enclosed in the refrigerant circuit. Caution A sort of Fluorocarbon (HFC) is used for this product as refrigerant. This product is specified by “Class1 Fluorocarbon Collection Destruction Law in Japan.” It is strictly forbitten by the law to emit the refrigerant to the atmosphere. Before you repair this product, you should collect the refrigirant with “Refrigerant collector.
i Safety Instructions i–4 Limited warranty and Disclaimer / Compliance Requirements The product used subject to the following “Limited warranty and Disclaimer“ and “Compliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered. Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2.
1 Name and Functions Parts 1 Parts Name and Functions 1-1 Parts Name and Functions y IDF1E ~ 3E Top Ventilation Grille (Outlet) Hot air will be exhausted from condenser by fan. No obstacles Switch with Lamp shall be allowed to place on top (ON/OFF Switch) of it or even close the grille. The lamp is continuously ON during normal operation. Use it for ON/OFF operations. Inspection Grille Evaporation thermometer From this grille, confirm the (EVAPORATING TEMP) discharge of drain.
1 Name and Functions Parts y IDF1E ~ 3E-10 (100V AC specification) Air inlet (IN) Port size: Rc3/8 Air outlet(OUT) Port size:Rc3/8 Front Rear Ventilation Grille (Inlet) Breathe in cooling air from this grille. Do not bung up with wall and so on. Earth Screw Connect the earth to this screw Power Cord Panel Lock Insert the plug to a 100V AC only Another one is on the right side outlet.
1 Name and Functions Parts y IDF4E ~ 15E Switch with Lamp (ON/OFF Switch) Right Side Ventilation Grille (Outlet) The lamp is continuously ON during normal operation. Use Waste heat will be exhausted it for ON/OFF operations. as hot air by the fan motor. Do not block with wall and so on. Evaporation Thermometer (EVAPORATING TEMP) Indicates the temperature of refrigerant of low-pressure side. Inspection Grille During normal driving, it Confirm the discharge of drain indicates in the green zone.
1 Name and Functions Parts y IDF4E ~ 15E-10(100V AC specification) Air Inlet (IN) Air Outlet (OUT) Front Screw for the Earth Connect the earth to this screw Power Cord Insert the plug to an outlet for exclusive use of 100V AC. Left Side Ventilation Grille (Inlet) Breathe in cooling air Fixing Screw for Front Panel from this grill. Do not Another one is on the right side. bung up with wall and so on.
2 Transportation / Installation 2 Transportation / Installation Warning Use the product in the right way. During Installation, operation, maintenance, and check, you should be careful in keeping the safety of human body. Caution Transportation, installation, and maintenance including dangerous work must be done by a personnel who has enough knowledge and experience about the product and the sysytem. 2-1 Transportation When you transport the product, you should follow these instructions below.
2 Transportation / Installation 2-2 Installation 2-2-1 Location The product should not be used or stored in the circumstances as follows. Those circumstances will cause not only malfunction but also failures. • Environment where the product is exposed to • Locations where danger of thunder is apparent. rainwater, moisture vapor, salty water, oil and • Locations by loading on vehicles, marine so on. vessels, and so on. • Locations where dust or particles are.
2 Transportation / Installation • Flash the piping sufficiently in order to avoid any foreign substances such as dust, sealing tape, liquid gasket, etc. when piping before piping connection.Foreign substances in the piping can cause cooling failure or drainage failure. • Use pipes and fittings that have enough endurance against the operating pressure and temperature. And connect it firmly to prevent air leakage.
2 Transportation / Installation 2–2–5 Electric Wiring Warning No one but qualified person should do the wiring work. ・ Before wiring, you must cut the power off for safety. Do not work under any energized conditions. ・ Supply power from a stable place, which is free from the effect of surge. ・ Ensure that a Ground Fault Circuit Interrupter(GFCI) with appropriate capacity for earth leakage and load is used in the power supply of the product to prevent electrical shock and burnout of the compressor motor.
2 Transportation / Installation 2-3 Cautions about Reinstallation Caution No one but someone who has enough knowledge about the product and incidental devices should reinstall in another place. And following instructions must be executed. If you move the product and reinstall it into another place after some operations (including trial running), instructions that are not only following ones but also all of those in the chapter 2 should be followed.
3 Operation / Shutdown 3 Operation / Shutdown Caution No one but someone who has enough knowledge and experience about the product and incidental devices should operate or shut down the product. 3-1 Check points before operation Before a trial running, check following points. • Installed Condition By visual inspection check that the product is installed horizontally. The product make sure the product is fixed enough with anchor bolts.
3 Operation / Shutdown Caution Avoid frequent On/Off operation, which can cause troubles. The auto drain used for the product has a structre that closes the valve with air pressure higher than 0.15MPa. Therefore, until the pressure increase, air will be emitted form the drain outlet at the begining of opening the IN side valve. Keep in mind that sometime the pressure cannot increase enough with air compressor that has low dischage flow rate. 3-3 Shutdown • Turn off the illuminated switch.
4 Maintenance 4 4-1 MAINTENANCE Daily Inspection Check following points during usual operations. If you find some problems, immediately stop the operation and refer to “Chapter 5 Troubleshooting” as soon as possible. • There is no air leakage • The running lamp is lighting during operation • Drain is being discharged from drain tube • The pointer of the evaporation thermometer indicates in the green zone when it is running with pressurized air supply.
4 Maintenance Warning ・ Maintenance of the air dryer should only be carried out by someone with sufficient knowledge and experience of air dryers and related equipment. ・ Before carrying out maintenance, the important warnings in this manual must be thoroughly read and understood. Danger ・ ・ ・ ・ ・ ・ When replacing or cleaning parts of the air dryer, be sure to remove the compressed air pressure inside the air dryer to “0”.
4 Maintenance Lock button 【IDF1E∼11E】 ・ Open the residual pressure release cock at the drain tube connection port to release air and drain fluid left in the product. Residual pressure rerease cock (Leave the drain tube connected and hold it with hand so that it does not get twisted.) ・ Because drain may be given by air pressure left in a product like a careful. Drain tube Open O S Close Drain tube rerease bush ・ Remove the drain tube.
4 Maintenance 【IDF15E】 Mark Lock button Lock button Residual pressure release cock Close Open Drain tube Drain tube release bush To remove the case assembly, turn it to 45°until the lock button and mark align. Then, pull it down slowly. ・ ・ pen the residual pressure release cock at the drain tube connection port to release air and drain fluid left in the product. (Leave the drain tube connected and hold it with hand so that it does not get twisted.) Remove the tube while pushing the release bush.
Air Dryer (IDF1E-10~IDF15E-10/20) 5 5 Troubleshooting Troubleshooting Should any problem occur, inspect the following table, and if the problem cannot be solved, shut off the power supply and then contact one of our sales offices for further instructions. Problem Air dryer does not operate and running lamp does not light on, even switch is ON. Running lamp extinguishes and compressor stops during operation but resumes normal operation illuminating the lamp after a period of time.
6 References References 6 Specifications 6-1 Model Specification Rated Condition Air Flow Rate m 3/min (ANR)(Note 1) IDF1E IDF2E IDF3E IDF4E Operating Range IDF11E IDF15E 50Hz 0.1 0.2 0.32 0.52 0.75 1.22 1.65 2.8 0.12 0.235 0.37 0.57 0.82 1.32 1.82 3.1 Operating Pressure 0.7MPa Inlet Air Temperature 35oC Ambient Temperature 32oC Pressurized Dew Point 10oC Compressed Air 5 ~ 50oC Inlet Air Temperature Inlet Air Pressure 0.15 ~ 1.
6 References 6-3 External Dimentions IDF1E / IDF2E / IDF3E A B E D Q Ventilation Air Inlet Port Size G Switch With Lamp Evaporation Thermometer Drain Check Window C Drain Check Window Air Outlet Port Size F Ventilation DraftAir Inlet Only IDF3E-20 L J Drain Tube (O.D.10 Length:0.82m) K P [AC200V specification] Power Supply Entry(φ17) M N [AC200V specification] Terminal Block H [AC100V specification] Power cord(Length:1.
6 References IDF15E B A E D Q Draft Air Outlet Air Outlet Port Size Switch With Lamp Air Inlet Port Size G Evaporation Thermometer C Draft Air Outlet Ventilation [AC200V specification] Terminal Block F Ventilation J Drain Tube (O.D.10 Length:0.82m) L P K N H M 4-φ13 [AC200V specification] Power Supply Entry(φ17) [AC100V specification] Power cord(Length:1.
6 References y IDF11E-10 ILS PTC AC100/100,110V (50/60Hz) C01 CM PC OLR PRS FM P y IDF11E-20 ILS PTC AC200/200,220 V L CM N OLR PE TB PRS P FM C11 ・ ・ IDF15E-10 IDF15E-20 TB PC ILS ILS TM OLR OLR RY RY CM CM RY C02 RY C02 C01 R C11 FM PRS FM P PRS P 6-4
6 References Compressed Air and Refrigerant Circuit / Operation Principles 6-5 y IDF1E Dorain Separator Compressed Air Inlet Compressed Air Outlet Compressed Air Circuit Humid hot air entering air dryer is cooled in Cooler the cooler. At this time, the condensed Dorain Outlet moisture is separated from the air by the Capillary Tube drain separator and automatically discharged.