Datasheet

Withstand pressure
Minimum unit setting
Rated pressure range
Secret code setting function
The key locking function keeps unauthorized users from
tampering with buttons.
Power-saving function
Power consumption is reduced by turning off the monitor
(power consumption reduced by up to 20%.)
Resolution-switch function
It reduces the monitor to flicker.
MPa/kPa switch function
Vacuum, compound and/or positive pressure can be
displayed both in MPa or kPa.
Bracket configuration allows mounting in four positions.
The clip type allows easy removal of fittings.
Fitting’s type and size can be changed.
Series
–0.100
to
1.000 MPa
1 MPa
0
–0.1 MPa
(–100 kPa)
ISE30A
(positive)
0.0
to
–101.0 kPa
101 kPa
0
ZSE30A
(vacuum)
–100.0 to 100.0 kPa
100 kPa
100 kPa
0
ZSE30AF
(compound)
0.001 MPa0.1 kPa
500 kPa
500 kPa
0.1 kPa
NPN or PNP open collector 1 output
NPN or PNP open collector 2 outputs
NPN or PNP open collector 1 output + Analog output (voltage or current)
Output
R1/8, NPT1/8 (M5 female threaded)
ø4, ø6, ø5/32, ø1/4 one-touch fittings
Piping
Set pressure range
–0.105
to
1.050 MPa
–105.0
to
105.0 kPa
10.0
to
–105.0 kPa
Mounting
example
Mounting
example
Bracket A Bracket B
Panel mount
Mountable side by side without clearance
One opening!
• Reduction of panel-cut job
• Space saving
Replaceable one-touch fittings
Connector cover added.
4-digit display allows easy reading of displayed values.
Example: 0.5 MPa
Lead wire
4-digit display
Additional functions
One-touch fitting
Clip
Lead wire with connector
(2 m)
Connector cover
Mounting
Series
1.5 MPa
Possible to check set-value during
key locking
Series 30A
(New)
(Accuracy does not changed, only displayed values.)
1/1000 1/100
Series 30
(Conventional)
How to Order
2-Colour Display High-Precision
Digital Pressure Switch
Series ZSE30A
(
F
)
/ISE30A
®
For vacuum/
compound pressure
ISE30A
For positive
pressure
01 N M
ZSE30A 01 N M
Rated pressure range
ISE30A
–0.1 to 1 MPa
Output
NPN open collector 1 output
PNP open collector 1 output
NPN open collector 2 outputs
PNP open collector 2 outputs
NPN open collector 1 output +
Analogue voltage output
NPN open collector 1 output +
Analogue current output
PNP open collector 1 output +
Analogue voltage output
PNP open collector 1 output +
Analogue current output
N
P
A
B
C
Note)
D
Note)
E
Note)
F
Note)
Rated pressure range
ZSE30A
ZSE30AF
0 to –101 kPa
–100 to 100 kPa
Option 1
Without lead wire
Lead wire with connector
(Lead wire length 2 m)
Note)
L
Lead wire with connector
(lead wire length 2 m)
Note)
and with connector cover
G
Note) For output types N and P, the number of core of lead wires will
be 3, and for other types, it will be 4.
Option 3
Symbol
Calibration
certificate
Y
W
K
T
R
Operating manual
Booklet
CD-ROM
With unit display
Note 2)
switching function
Fixed SI unit
Note 3)
With unit display
Note 2)
switching function
(Initial value PSI)
P
M
Display unit
Note 2) Under the New Measure-
ment Law, sales of switches
with the unit switching func-
tion have not been allowed
for use in Japan.
Note 3) Fixed unit kPa, MPa
Option 2
None
Bracket
A
A1
Bracket B
A2
Panel mount adapter
B
Panel mount adapter + front protection cover
D
Piping
R1/8 (M5 female threaded)
NPT1/8 (M5 female threaded)
One-touch fitting ø4 mm, ø5/32 inch
One-touch fitting ø6 mm
One-touch fitting ø1/4 inch
One-touch fitting ø4 mm, ø5/32 inch
One-touch fitting ø6 mm
One-touch fitting ø1/4 inch
01
N01
C4H
C6H
N7H
C4L
C6L
N7L
Straight type
Elbow type
Note) Made to Order
Note) Made to Order
Note 1) Made to Order
Note)
Note 1)
Connector cover
Features 1