Datasheet
Range
For vacuum
pressure
For compound
pressure
For positive
pressure
Rated pressure range
0.0 to –101.0 kPa
A
10.1 kPa
B
0
C
–101.0 kPa
–100.0 to 100.0 kPa — –100.0 kPa 100.0 kPa
–0.100 to 1.000 MPa
–0.100 to 2.00 MPa
–0.100 MPa
–0.100 MPa
Note)
0
0
1.000 MPa
2.00 MPa
Displays the current pressure, set mode, selected
display unit, and error code. Always use red or
green display; or switch between green and red
according to the output. Four different display
settings are available.
Lights up when OUT1 is turned ON.
Output (OUT1) display (Orange)
Lights up when OUT2 is turned ON.
Output (OUT2) display (Orange)
Use this button to change the mode or confirm the
set-value.
SET button
Use this button to select the mode or increase the
ON/OFF set-value.
It is also used for switching to the peak display
mode.
button
Use this button to select the mode or decrease the
ON/OFF set-value.
It is also used for switching to the bottom display
mode.
button
Analog Output
Descriptions
Voltage output
1
0.6
Pressure
Analog output [V]
5
BA
C
Current output
4
2.4
Pressure
Analog output [mA]
20
BA
C
Note) Analog output is 0.8 [V] or 3.2 [mA] at the pressure A.
LCD
734
Series ZSE80/ISE80
P0694-P0755-E.qxd 08.8.27 6:29 PM Page 734