Electro-Pneumatic Regulator Electronic Vacuum Regulator New IP65∗ RoHS compliant ∗ ITV009/209 are IP65 equivalent. Stepless control of air pressure proportional to an electrical signal Fieldbus compatibility added to Series ITV1000/2000/3000 specifications! Reduced wiring Applicable Fieldbus protocols 98(108) Note 2) Built-in communication board, so no converter needed.
Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal.
Electro-Pneumatic Regulator Series ITV1000/2000/3000 How to Order ITV 3 0 1 0 0 1 S 2 Q CE compliant Model 1 2 3 Q 1000 type 2000 type 3000 type CE compliant ∗ For detailed information on CE marked models, refer to SMC's website. Pressure range 1 3 5 0.1 MPa 0.5 MPa 0.9 MPa Made to Order Specifications Power supply voltage 0 1 See pages 11, 25, and 26 for details.
Electro-Pneumatic Regulator Series ITV1000/2000/3000 Standard Specifications Model ITV101 Note 10) ITV201 ITV301 Minimum supply pressure Maximum supply pressure Set pressure range Note 1) ITV1000 ITV2000 Voltage Power supply Current consumption Current type Note 2) Input signal Input impedance Note 3) Output signal (monitor output) ITV3000 Fieldbus-compatible model JIS Symbol Set pressure +0.1 MPa 1.0 MPa 0.2 MPa 0.005 to 0.1 MPa 0.005 to 0.
Series ITV1000/2000/3000 Standard specifications Combinations Combination not possible Combination possible REGULATOR Specifications e L-bracket 178 qAF30 1 Set pressure max. 0.5 MPa 3 Set pressure max. 0.
Electro-Pneumatic Regulator Series ITV1000/2000/3000 Working Principles When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF. Therefore, supply pressure passes through the air supply solenoid valve q and is applied to the pilot chamber e. The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r.
Series ITV1000/2000/3000 Series ITV101 25 50 75 0.5 Return 0.0 –0.5 –1.0 100 1.0 Out 0 Pressure characteristics 0.5 0.0 –0.5 –1.0 25 Input signal (%F.S.) 50 0 100 75 2 4 Input signal (%F.S.) Set pressure: 0.05 MPa Flow characteristics 1.0 Supply pressure: 0.2 MPa Relief flow characteristics Set point 0.0 –0.5 8 10 Supply pressure: 0.2 MPa 0.25 Set pressure (MPa) 0.5 6 Repetition 0.15 Set pressure (MPa) Output deviation factor (%F.S.) Repeatability 1.
Electro-Pneumatic Regulator Series ITV1000/2000/3000 Series ITV301 Linearity Set pressure (MPa) 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 25 50 75 1.0 0.5 Out 0.0 Return –0.5 –1.0 100 0 Input signal (%F.S.) Set pressure: 0.05 MPa 75 0.0 –0.5 0.2 Supply pressure (MPa) 0.0 –0.5 0 2 4 0.3 Supply pressure: 0.2 MPa 8 10 Relief flow characteristics Supply pressure: 0.2 MPa 0.25 0.10 0.05 0.00 6 Repetition Set pressure (MPa) Set point 0.1 0.5 –1.0 100 0.15 0.5 0.
Series ITV1000/2000/3000 Series ITV103 Hysteresis Output deviation factor (%F.S.) 0.6 Set pressure (MPa) 0.5 0.4 0.3 0.2 0.1 0.0 0 25 50 75 Out 0.5 Return 0.0 –0.5 –1.0 100 Repeatability 1.0 0 Set pressure: 0.2 MPa Flow characteristics 75 –0.5 0 2 4 0.0 –0.5 Supply pressure: 0.7 MPa Relief flow characteristics 0.3 0.2 0.1 0.6 0.8 8 10 Supply pressure: 0.7 MPa 0.8 0.7 0.4 0.0 6 Repetition Set pressure (MPa) Set point 0.4 0.0 100 0.5 0.
Series ITV1000/2000/3000 Electro-Pneumatic Regulator Series ITV303 Linearity Hysteresis Set pressure (MPa) 0.5 0.4 0.3 0.2 0.1 0.0 0 25 50 75 0.5 Out 0.0 Retirm –0.5 –1.0 100 0 25 Input signal (%F.S.) Pressure characteristics 50 75 Set pressure: 0.2 MPa Flow characteristics Supply pressure: 0.7 MPa –0.5 0 2 4 –0.5 Supply pressure (MPa) 0.8 10 Supply pressure: 0.7 MPa 0.7 0.4 0.3 0.2 0.0 8 0.8 0.1 0.6 6 Relief flow characteristics Set pressure (MPa) 0.
Series ITV1000/2000/3000 Series ITV105 Linearity Hysteresis 0.7 0.6 0.5 0.4 0.3 0.2 0.1 25 50 75 1.0 Out 0.5 0.0 Return –0.5 0 25 50 Input signal (%F.S.) 75 0.5 Set point 0.0 –0.5 0 0.6 0.8 2 4 6 Flow characteristics Supply pressure: 1.0 MPa Relief flow characteristics 1.0 0.9 1.0 0.9 0.8 0.8 0.7 0.6 0.5 0.4 0.3 0.2 1 0.0 1.2 8 10 Repetition Supply pressure: 1.0 MPa 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.4 –0.5 100 Set pressure (MPa) Set pressure: 0.4 MPa 1.0 –1.0 0.
Electro-Pneumatic Regulator Series ITV1000/2000/3000 Series ITV305 Linearity Hysteresis 1.0 0.9 0.7 Set pressure (MPa) 1.0 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0 25 50 75 100 0.5 Out 0.0 Return –0.5 –1.0 0 25 Input signal (%F.S.) 50 75 100 Set pressure: 0.4 MPa Flow characteristics 1.0 Set pressure (MPa) 0.5 Set point 0.0 –0.5 –1.0 0.6 0.8 0.0 –0.5 –1.0 0 2 Supply pressure: 1.0 MPa 1.0 Supply pressure (MPa) 1.2 6 Relief flow characteristics 1.0 0.9 1.0 0.9 0.8 0.8 0.
Series ITV1000/2000/3000 Dimensions ITV10 Flat bracket 12.5 (11) M12 x 1 Cable connection threads Rc 1/8 Pressure gauge connection port Rc 1/8 Exhaust port EXH (3) 71 OUT (2) SUP (1) 12 11 19.5 Solenoid valve EXH M3 x 0.5 Solenoid valve EXH 2 x Rc1/8, 1/4 SUP port, OUT port Flat bracket KT-ITV-F1 (Option) Flat bracket KT-ITV-F1 (Option) 40 4 x M4 x 0.
Electro-Pneumatic Regulator Series ITV1000/2000/3000 Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C) M12 x 1 Reverse connector M12 x 1 DeviceNet™/ITV100-DN M12 x 1 Communication cable connection thread 10 10 M12 x 1 Communication cable connection thread M12 x 1 Power cable connection thread (11) (53) M12 x 1 Power cable connection thread BUS adapter 8.5 10 10 (11) CC-Link/ITV100-CC 8.5 RS-232C/ITV100-RC M12 x 1 Power cable connection thread 98 (11) M3 x 0.
Series ITV1000/2000/3000 Dimensions ITV20 Flat bracket Note) Do not attempt to rotate, as the cable connector does not turn. 12.5 M12 x 1 (11) Cable connection thread Rc 1/4 Exhaust port 13.5 Solenoid valve EXH 93 M5 x 0.8 Solenoid valve EXH SUP (1) OUT (2) 12 19 EXH (3) Flat bracket KT-ITV-F2 (Option) 2 x Rc 1/4, 3/8 Flat bracket KT-ITV-F2 (Option) 36 SUP port, OUT port 4 x M5 x 0.
Electro-Pneumatic Regulator Series ITV1000/2000/3000 Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C) DeviceNet™/ITV200-DN M12 x 1 Communication cable connection thread 10 10 M12 x 1 Communication cable connection thread M12 x 1 Power cable connection thread (11) (53) M12 x 1 Reverse connector M12 x 1 BUS adapter 8.5 10 10 M12 x 1 Power cable connection thread (11) CC-Link/ITV200-CC 8.
Series ITV1000/2000/3000 Dimensions ITV30 Note) Do not attempt to rotate, as the cable connector does not turn. 12.5 M12 x 1 Cable connection thread (11) Flat bracket Rc 1/4 Pressure gauge connection port 35.7 Solenoid valve EXH 114 M5 x 0.8 Solenoid valve EXH Rc 1/2 Exhaust port SUP (1) OUT (2) 30 12 22 25 8 EXH (3) Flat bracket KT-ITV-F2 (Option) 2 x Rc 1/4, 3/8, 1/2 SUP port, OUT port Flat bracket KT-ITV-F2 (Option) 4 x M5 x 0.
Electro-Pneumatic Regulator Series ITV1000/2000/3000 Dimensions (CC-Link, DeviceNet™, PROFIBUS DP and RS-232C) M12 x 1 Reverse connector M12 x 1 BUS adapter DeviceNet™/ITV30-DN M12 x 1 Communication cable connection thread (11) (53) M12 x 1 Communication cable connection thread M12 x 1 10 10 Power cable connection thread M12 x 1 Power cable connection thread 10 10 8.5 (11) CC-Link/ITV30-CC 8.5 35.
Series ITV1000/2000/3000 Made to Order Made to Order Specifications 1 Contact SMC regarding detailed dimensions, specifications and delivery times. 1 16 Points Preset Input Type 3 Reverse Type In compliance with the input, inverse proportional pressure is displayed. Able to control 16-point-pressure by 4 bit switching input 00 4 2 3 X156 ITV10 X321 X156 ITV20 X321 X156 ITV30 X321 ITV20 00 4 2 3 ITV30 00 4 2 3 Note 1) in part number is the same model no. for the standard products.
Series ITV1000/2000/3000 Made to Order Made to Order Specifications 2 Contact SMC regarding detailed dimensions, specifications and delivery times. 6 High-Speed Response Time Type Pressure response with no load is approx. 0.1 sec. ITV 2 0 1 0 01 2 S X154 High-speed response time specifications Model 1 2 1000 type 2000 type Pressure range 1 3 5 Power supply voltage 0 1 24 VDC 12 to 15 VDC Pressure display unit 0.1 MPa 0.5 MPa 0.
Safety Instructions Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Series ITV0000/1000/2000/3000 Specific Product Precautions 1 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions. Series ITV0000/009 Precautions Air Supply Handling Caution Caution 1. Install an air filter near this product on the supply side. Select a filtration degree of 5 µm or less. 2.
Series ITV0000/1000/2000/3000 Specific Product Precautions 2 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions. Series ITV1000/2000/3000/209 Precautions Piping Operating Environment 1. Screw piping together with the recommended proper torque while holding the side that has female threads. 1.
Series ITV0000/1000/2000/3000 Specific Product Precautions 3 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions. Series ITV1000/2000/3000/209 Precautions Handling Handling Caution 1. Do not use a lubricator on the supply side of this product, as this can cause malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of this equipment. 2.
Series ITV0000/1000/2000/3000 Specific Product Precautions 4 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions. Series ITV1000/2000/3000/209 Precautions Wiring Caution Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple.
Series ITV0000/1000/2000/3000 Specific Product Precautions 5 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions. Series ITV1000/2000/3000/209 Precautions Set Pressure Range The regulating pressure range, by unit of standard measured pressure, is shown in the table below. Regulating pressure range, by unit of standard measured pressure Regulating pressure range Unit MPa ITV01 0.
Series ITV0000/1000/2000/3000 Specific Product Precautions 6 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) for Common Precautions. Series ITV009/209 Precautions Handling Caution 1. Connect the vacuum pump to the port, which is labeled “VAC”. 2.
EUROPEAN SUBSIDIARIES: Austria SMC Pneumatik GmbH (Austria). Girakstrasse 8, A-2100 Korneuburg Phone: +43 2262-622800, Fax: +43 2262-62285 E-mail: office@smc.at http://www.smc.at France SMC Pneumatique, S.A. 1, Boulevard de Strasbourg, Parc Gustave Eiffel Bussy Saint Georges F-77607 Marne La Vallee Cedex 3 Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010 E-mail: contact@smc-france.fr http://www.smc-france.