Spec Sheet

Warning Warning
Construction/Dimensions
AD402
Component Parts
Replacement Parts
Model/Specifications
Drainage is automatically
discharged in a reliable
manner, without requiring
human operators.
Highly resistant to dust and corro-
sion, operates reliably, and a bowl
guard is provided as standard
equipment.
Option Specifications
1. Use auto-drain under the following
operating conditions, or it will lead to
malfunctions.
To connect a drain discharge pipe, use
a pipe with a minimum bore of ø10, and
a maximum length of 5 m. Avoid using a
riser pipe.
AD600
•Working principle (AD402)
When no pressure is applied internally to bowl !0, float t descends of
its own weight and valve o closes chamber hole y. Piston i is
pushed down by spring !1, and the drainage passes through the
chamber’s elongated hole !2 to enter the housing and is discharged.
When pressure is applied internally to the bowl:
When pressure is larger than 1 MPa, it overcomes the force of spring
!1, allowing piston i to ascend, and comes in contact with O-ring r.
Thus, the inside of bowl !0 is isolated from the outside.
When drainage has accumulated:
Float t ascends due to flotation and opens the chamber
,
s hole y,
allowing the pressure to enter chamber y. Piston i descends due to
the force of the internal pressure and spring !1, and the accumulated
drainage is discharged through drain guide !3.
No.
q
Description
Body
Material
Aluminum die-casted
No.
w
Description
113136
20062
AD34PA
Model
AD402
JIS B 2401G-100
20025A
AD600
Material
NBR
Stainless steel
O-ring
e
(1)
i
Gauze
Internal assembly
Piston assembly
201037P
!4
Valve assembly
Note 1) Internal assembly: Assembly for parts r to !2 except !0.
Note 2) Part no. for bowl assembly: AD34
Note 3) Part no. for bowl !0: 201016
AD402
AD600
Proof pressure
Max. operating pressure
Operating pressure range
Note)
Ambient and fluid temperature
Port size
Drain discharge port size
Weight (g)
Model
1.5 MPa
1.0 MPa
0.1 to 1.0 MPa
620
–5 to 60°C (No freezing)
Rc , ,
1.5 MPa
AD402 AD600
Note) Use for air compressor with flow larger than 400 l/min (ANR).
1
4
3
8
3
8
1
2
1.0 MPa
0.3 to 1.0 MPa
2100
–5 to 60°C (No freezing)
Rc
,1
,1
3
4
3
4
Metal bowl AD402- -2
Related Products: Auto Drain Valve
AD402/600
Valve
assembly
Body
O-ring
Gauze
Valve
Chamber
Float
Case
Long hole
of chamber
Drain guide
Lever
Spring
Piston
O-ring
Drain
Piston assembly
Body
O-ring
JIS Symbol
Selection Piping
1. Use auto-drain under the following
operating conditions, or it will lead to
malfunctions.
1) Operate the compressor above 3.7 kw
{400 l/min (ANR)}.
2) Use AD402 at an operating pressure
above 0.1 MPa and AD600 above 0.3
MPa.
Precautions
Be sure to read before handling. Refer to pages 14-21-3 to 4 for Safety
Instructions and Common Precautions on the products mentioned in this
catalog, and refer to pages 14-14-6 to 8 for Precautions on every series.
Rc 3/4, 1
Rc 3/4, 1
Rc 1/4, 3/8, 1/2
Rc 3/8
14-20-49
HA
AT
ID
AMG
AFF
AM
Misc.

Summary of content (5 pages)