Datasheet

41
Specific Product Precautions 4
Be sure to read before handling. Refer to page 37 for safety instructions.
Series PF2A/PF2W
Sensor
1
l
/min 5 l/min
10 l/min
20 l/min
50 l/min 100 l/min 200 l/min 500 l/min
Flow rate range
PF2A510
PF2A550
PF2A511
PF2A521
PF2A551
Sensor
Flow rate range
PF2W504
PF2W504T
PF2W520
PF2W520T
PF2W540
PF2W540T
PF2W511
Rated flow range of sensor
Set flow rate range of sensor
0.5 l/min 4 l/min
0.35 l/min
4.5
l/min
2
l/min
1.7
l/min
40
l/min
45 l/min
16
l/min
17
l/min
5
l/min
3.5
l/min
10 l/min
100
l/min
110
l/min
7
l/min
1 l/min 10 l/min
0.5 l/min
10.5
l/min
5
l/min
2.5
l/min
100
l/min
105
l/min
50
l/min
52.5
l/min
10
l/min
5
l/min
20 l/min
200
l/min
210
l/min
10
l/min
50 l/min
500
l/min
525
l/min
25
l/min
0.5 l/min
2 l/min
5 l/min
10 l/min 20 l/min 40 l/min 100 l/min
<
For Air/PF2A
>
<
For Water/PF2W
>
Caution
Set Flow Rate Range and Rated Flow Range
Set the flow rate within the rated flow range.
The set flow rate range is the range of flow rate that can be set on the controller.
The rated flow range is the range that satisfies the sensor’s specifications (accuracy, linearity etc.).
It is possible to set a value outside of the rated flow range, however, the specification is not be guaranteed.