Datasheet

Page 1432
Sensors, Switches
Series PS1000 Simple Electronic Pressure Switch
Simple Electronic Pressure Switch
Series PS1000/1100
Features
How to Order Specifications
Dimensions
"Air checker" for air or dry inert gases
Gives an output when air or vacuum is present
Positive pressure and vacuum versions
Small and lightweight construction
Adjustable switching point
Fits into a 6mm one-touch fitting
Lead wire length
L
3 m
Piping specifications
R06
Output specifications
PS LQ00 R06
ø6 reducer
Switch Specifications
Setting pressure
t
Switch turns ON when the pressure is larger
than setting pressure.
Switch turns ON when the pressure is smaller
than setting pressure.
Pressure
(MPa)
PS1000 ON
OFF
PS1100 ON
OFF
0.4
0.2
0
-0.1
Use the calibration adjustment to set
ON pressure.
Rotate clockwise to increase pressu-
re setpoint. For setting vacuum, rota-
te counterclockwise.
In the event of setting, use a flat
head screwdriver suited for the
groove of a trimmer, and rotate it
lightly with a finger tip.
Rotation angle of the trimmer is 220˚ .
There is a stop provided to prevent the trimmer from rotating beyond its
limits. Rotation beyond the limit can damage the trimmer. Adjust the
trimmer gently within the rotation angle.
+
High
pressure
High
vacuum
Pressure
setting trimmer
220˚
Left end adjustment limit Right end adjustment limit
Pressure Switch Calibration
Trimmer
Applicable One-touch fittings
KQ
H L T
06-M5
Other Series KQ/KS
Series KJ
Series KJ (-X20)
S Y
A
16
13
14.5
16
10
A
30
ø6 reducer
AIRCHECKER
PS1000-R06L
PRESS. –0.10 to 45 MPa
{–1 to 4.6 kgf/cm
2
}
MADE IN JAPAN
+
30
25.5
3000
13
Calibration trimmer
LED display
Lead wire length
10
11
2-wire system (For positive pressure)
2-wire system
(For vacuum and residual pressure)
10
Model
Switch output
Max. operating
pressure
Regulating
pressure range
Fluid
Indication light
Temperature
characteristics
Repeatability
Hysteresis
Load voltage
Load current
Leakage
Int. voltage drop
Operating
temperature range
Insulation
resistance
Withstand voltage
Vibration
resistance
Impact resistance
Weight
Port size
Enclosure
Lead wire
PS1000-R06L
Present pres.Setting pres.: ON
–0.1 to 0.45 MPa
PS1100-R06L
Present pres.Setting pres.: ON
–0.1 to 0.4 MPa
1 MPa
Air/Non-corrosive gas
ON: When red LED turns on
±3% F.S. or less
±1% F.S. or less
4% F.S.
12 to 24 VDC (Ripple ±10% or less)
5 to 40 mA
1 mA or less
5 V or less
0 to 60°C (With no condensation)
Between external terminals and case
2 M (500 VDC by megameter)
Between external terminals and case
1000 VAC 50/60 Hz for 1 min.
10 to 500 Hz Pulse width 1.5 mm or acceleration 98 m/s
2
(at the smaller vibration) in X, Y, Z directions (2 hours)
980 m/s
2
X, Y, Z directions (3 times for each direction)
5 g (Excluding lead wire)
ø6 reducer
IP40
Grommet oil-proof cabtire cord 2-wires ø2.55, 0.18 mm
2
, 3 m