Datasheet

Page 1420
Sensors, Switches
Series PSE560 Pressure Sensor for General Fluids
Pressure Sensor For General Fluids
Series PSE560
Features
How to Order
Remote sensor for fluids and wet air
All wetted parts stainless steel
1-5v or 4-20mA analogue output
Choice of connection thread types
Robust metal case
IP65 splashproof construction
Available for positive and vacuum pressures
Can be specified with connector for SMC display units
Accessories
Description
ZS-28-C 1 pc.
Part no. Note
Connector for PSE300
PSE56 0 01
Port size
0
1
3
4
Positive pressure (0 to 1 MPa)
Vacuum (0 to –101 kPa)
Compound pressure (–100 to 100 kPa)
Positive pressure (0 to 500 kPa)
01
02
C01
A2
B2
R 1/8 (With M5 female thread)
R 1/4 (With M5 female thread)
1/8
URJ 1/4
TSJ 1/4
Option (Connector)
Nil C2
Without
Connector for PSE300 or
PSE200 displays
1 pc.
Voltage output type 1 to 5 V
Current output type 4 to 20 mA
Nil
28
Pressure sensing range
Output specifications
Note 1)
Current output type cannot be connected to PSE20
or
PSE30
.
Note 2) The connector is not connected to the cable and is
supplied loose at the time of shipment.
®
C2
Specifications
Conforms to CE marking and UL (CSA) standards.
Model PSE56--28
Fluid, including gas, that will not corrode Stainlesss steel 316L
12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection)
±1% F.S. or less
±0.5% F.S. or less
±0.2% F.S. or less
±0.3% F.S. or less
IP65
Operating: –10 to 60˚C, Stored: –20° to 70°C (No condensation or freezing)
Operating/Stored: 35 to 85% RH (No condensation)
250 VAC for 1 minute between live parts and case
50 M
between live parts and case (at 50 VDC)
±2% F.S. or less (0 to 50˚C, based on 25˚C), ±3% F.S. or less (–10 to 60˚C, based on 25˚C)
Fluid
Power supply voltage
Current consumption
Output specification
Accuracy
(Ambient temperature of 25˚C)
Linearity
Repeatability
Power supply voltage effect
Temperature characteristics
Enclosure
Operating temperature range
Operating humidity range
Withstand voltage
Insulation resistance
Resistance
PSE56-
Model
0 to –101 kPa
500 kPa
–100 to 100 kPa
500 kPa
Rated pressure range
Proof pressure
0 to 1 MPa
1.5 MPa
PSE561PSE560
0 to 500 kPa
750 kPa
PSE563 PSE564
10 mA or less
Analog output 1 to 5 V (Within rated pressure range)
Output impedance: Approx. 1 k
Analog output 4 to 20 mA (Within rated pressure range)
Allowable load impedance: 500
or less (at 24 VDC)
100
or less (at 12 VDC)

Summary of content (2 pages)