Compact Proportional Solenoid Valve Repeatability: 3% or less Hysteresis: 10% or less Flow rate control range Note) Fluid Air, Inert gas 0 to 6 l /min 0 to 100 l /min Series PVQ10 PVQ30 Note) Varies depending on the model. Control the flow rate smoothly according to the current Flow Characteristics Flow rate (l/min) inc Cu re rre as n ing t C de urre cr nt ea sin g Max.
Service life: Lasts 25 million cycles. (PVQ30) (SMC in-house life test conditions) Specially coated sliding surface realised 25 million cycles within a set operation range O-ring O-ring Body material: Brass (C36) (PVQ10), Brass (C37) or Stainless steel (PVQ30) Seal material: FKM (PVQ10, PVQ30) Valve returns to closed position when power supply is turned off. Leakage amount: 5 cm3/min or less at OFF Can be used for vacuum applications. (Minimum operating pressure 0.
Applications Air-blow • Blow-off of debris or water. Work transportation Spin control of handpiece Blood pressure gauge Vacuum chamber supply flow control Smooth air supply/exhaust is possible by reducing the initial air supply. Prevents dust being stirred up inside the chamber. Supply Exhaust P Vacuum pump Model Piping type PVQ13 PVQ31 PVQ33 Base mounted Body ported Base mounted Bracket (Option) Valve construction Direct operated poppet Direct operated poppet N.C. 4 0.
Series PVQ Model Selection ∆P = (P1 – P2) MPa ∆P: Pressure differential P1 : Inlet pressure P2 : Outlet pressure Condition 1. P1 = 0.7 MPa, P2 = 0 MPa (Atmospheric pressure) Refer to curve A when ∆P is 0.7 MPa. Ex) At increasing currents, when a 140 mA current is applied, a flow rate of 85 l/min is achieved. (See q.) If current decreases at this point, the flow rate may not change by 135 mA due to hysteresis. (See w.
Model Selection Q. Required flow rate = 0 to 75 l/min. P1 = No conditions, P2 = 0 MPa (Atmospheric pressure) In this case, all of PVQ30 series orifice sizes satisfy the required flow rate. (Flow rate when rated current is applied) The table below shows the pressure differentials needed to satisfy the required flow rate. In the flow rate characteristic charts, a pressure differential over the flow rate indicated by the dashed line (75 l/min.) up to the max.
Compact Proportional Solenoid Valve Series PVQ10 How to Order Base mounted PVQ 13 5 L 03 M5 A Body / Seal material Valve type 13 N.C. Symbol Body Seal A Brass (C36) FKM Voltage 5 6 24 VDC Port size 12 VDC - Without sub-plate (with mounting screw M1.7 x 17L, 2 pcs.) M5 With sub-plate M5 x 0.8 Electrical entry L M Mounting screw L plug connector Sub-plate M plug connector Orifice size Symbol Orifice dia. Max. operating pressure 03 04 06 08 0.3 mmø 0.7 MPa 0.4 mmø 0.
Series PVQ10 Compact Proportional Solenoid Valve Flow Characteristics PVQ10 (ø0.3) PVQ10 (ø0.4) 7 7 ∆P = 0.7 MPa ∆P = 0.5 MPa 5 4 ∆P = 0.35 MPa 3 ∆P = 0.2 MPa 2 1 0 24 VDC → 0 12 VDC → 0 ∆P = 0.7 MPa 6 Flow rate (l/min) Flow rate (l/min) 6 ∆P = 0.5 MPa 5 ∆P = 0.35 MPa 4 3 ∆P = 0.
Series PVQ10 Dimensions L plug connector 6 25.6 2 x ø2.7 Mounting hole 11 14 ≈ 300 PVQ13-L--M5 M5 1 (IN port) M5 2 (OUT port) 4.8 1 (IN port) ø1.4 2 (OUT port) ø1.4 6.8 Sub-plate Round head combination screw 35 IN O-ring 2.7 2 x ø2.7 15 2.3 OUT O-ring 16 Interface 13.7 10 3.1 4 23 M plug connector PVQ13-M--M5 ≈ 300 41.2 M5 1 (IN port) 24.6 2 x ø2.7 Mounting hole 11 6 14 36.1 4.8 1 (IN port) ø1.4 2 (OUT port) ø1.4 6.
Compact Proportional Solenoid Valve Series PVQ30 How to Order Option Port size Valve type 01 31 N.C. Body ported Base mounted 1/8 (6A) - None F Foot bracket ∗ Bracket is not mounted but is provided at the time of shipment. PVQ 31 5 G 16 01 PVQ 33 5 G 16 01 Body / Seal material Valve type 33 N.C. Body - Brass (C37) H Stainless steel Voltage 5 6 24 VDC Electrical entry: Grommet Orifice size 23 40 FKM Thread type (with sub-plate) 12 VDC Symbol Orifice dia. 1.
Series PVQ10 Flow Characteristics Air PVQ30 (ø2.3) PVQ30 (ø1.6) 120 120 ∆P = 0.7 MPa ∆P = 0.5 MPa 80 ∆P = 0.35 MPa 60 ∆P = 0.2 MPa 40 ∆P = 0.25 MPa 80 ∆P = 0.18 MPa 60 ∆P = 0.1 MPa 40 20 20 0 24 VDC → 0 12 VDC → 0 ∆P = 0.
Compact Proportional Solenoid Valve Series PVQ30 Dimensions 15 PVQ31 2 x M3 x 5 ≈ 300 11 5 8 29.5 ≈ 61 ø20.5 20.5 Rc 1/8 2 (OUT port) 25 Rc 1/8 1 (IN port) 27 2 x ø3.5 20 20 Bracket assembly ≈ 300 ø20.5 22 2 x ø3.4 Mounting hole 11 16 ≈ 49 15.5 PVQ33 27 15 8.7 IN O-ring Interface Rc 1/8 1 (IN port) 30 ø3.8 2 x ø2.8 1.8 Sub-plate 30 27 1.8 2 x ø3.4 Base mounting hole 15.5±0.1 28 6 23 20 23 Rc 1/8 2 (OUT port) 3 21.
Glossary Proportional control The fluid is controlled proportionally according to an input signal (current). Max. operating pressure differential Indicates the max. pressure differential (difference between the inlet and the outlet pressure) which is allowed for operation with the valve closed or open. Max. operating pressure Indicates the limit pressure that can be applied to the inlet.
Series PVQ Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices.
2/3 Port Process Valves Precautions 1 Be sure to read this before handling. For detailed precautions on every series, refer to main text. Design Warning 1. Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2.
2/3 Port Process Valves Precautions 2 Be sure to read this before handling. For detailed precautions on every series, refer to main text. Piping Mounting Caution Warning 1. If air leakage increases or the equipment does not operate properly, stop operation. 4. Always tighten threads with the proper tightening torque. After mounting is completed, confirm that it has been done correctly by performing a suitable function test.
2/3 Port Process Valves Precautions 3 Be sure to read this before handling. For detailed precautions on every series, refer to main text. Operating Environment Maintenance Warning Warning 1. Do not use the valves in an atmospheres having corrosive gases, chemicals, salt water, water, steam, or where there is direct contact with any of these. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4.
Series PVQ Specific Product Precautions Be sure to read this before handling. Power Source Selection Caution Operation in Vacuum Caution This product makes proportional control possible with constant current. When the product is used in vacuum, apply vacuum pressure to A (2) port. If controlled with voltage, the output flow rate cannot be kept constant due to current fluctuation. Use a stable DC power source with sufficient capacity without much ripple.
EUROPEAN SUBSIDIARIES: Austria SMC Pneumatik GmbH (Austria). Girakstrasse 8, A-2100 Korneuburg Phone: +43 2262-62280, Fax: +43 2262-62285 E-mail: office@smc.at http://www.smc.at France SMC Pneumatique, S.A. 1, Boulevard de Strasbourg, Parc Gustave Eiffel Bussy Saint Georges F-77607 Marne La Vallee Cedex 3 Phone: +33 (0)1-6476 1000, Fax: +33 (0)1-6476 1010 E-mail: contact@smc-france.fr http://www.smc-france.