2. Specifications
Port size Rc1/4, NPT1/4, G1/4, Rc3/8, NPT3/8, G3/8
Fluid Air, Nitrogen, Carbon dioxide gas(gas)
Rated flow 500L/min (ANR)
*1
Nominal filtration rating
*2
0.01μm (99.99%)
*5
Operating pressure range
*3
-100kPa to 1.0MPa
(For nitrogen, Carbon dioxide gas: 0.99MPa)
Operating temperature 5 to 45
o
C
Initial pressure drop 0.03MPa(Inlet pressure 0.7MPa, at max. flow rate)
Element proof differential pressure
*4
0.5MPa
Proof pressure 1.5MPa
Element life 1 year, or when the pressure drop reaches 0.1 MPa
Materials
of parts in
contact
with fluid
Metal parts Stainless steel
Resin/Rubber parts
Materials compliant with FDA/Food Sanitation Law
Weight
Port size 1/4 450g
Port size 3/8 430g
*1 Maximum flow rate at inlet pressure 0.7 MPa and pressure drop 0.03 MPa.
*2 Measured under SMC’s specified conditions.
*3 The maximum operating pressure varies depending on temperature.
*4 This means that the element does not break at 0.5 MPa.
*5 The bacteria removal filter is intended to filter solid particles. It is not suitable for the separation
of water and oil.
Bacteria removal performance (bacteria capture performance of filter element) LRV ≥ 9
LRV (Log Reduction Value) indicates the bacteria capture performance.
LRV=Log
10
[Demonstrated by a third-party research institution (Test reference report No.: 2019D-BT-548)]
* This does not guarantee that all bacteria will be removed. Not for eliminating the virus. This is
the data evaluated based on JIS K 3835.
A A: Total number of test bacteria applied upstream of the filter
B B: Total number of test bacteria after passing through the filter (downstream)
2021-09-1615:31
DP 097499