Datasheet
How to Order
Maximum Operating Pressure
Soft Fluoropolymer Tubing
Metric Size
Series TD
Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the sur-
ge pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubes.
Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tube burs-
ting.
Note 2) Do not use this product in a manner in which the tube is not fixed.
Observe the lesser value of the maximum operating pressure between the tube and fitting.
A material change over a long duration or due to high-temperature may cause leakage. Perform periodic
maintenance and replace with a new product immediately when abnormalities are detected.
Refer to the “Maintenance” precautions in the TD/TID tubing.
For other precautions, see the “Fittings & Tubing” precautions in the “Best Pneumatics catalogue".
When using the fluoropolymer fittings, please refer to the precautions in the relevant catalogue
CAT. ES70-17.
Note 3) The minimum bending radius is the representative value measured as shown below.
• Use a tube above the recommended minimum bending radius.
• The tube may be bent if used under the recommended minimum bending radius. Therefore, refer to
the refraction value and make sure that the tube is not bent or flattened.
• Please note that the refraction value is not warranted because of the value when 2R is measured by
the method shown above on the left if the tube is bent or flattened, etc.
Model/Specifications
Metric size
Insert fitting KF series
Stainless steel 316 insert fitting KFG series
Miniature fittings M, MS series (Hose nipple type)
Fluoropolymer fitting LQ2 series
Model
Size
TD0425
Tubing O.D. (mm)
Tubing I.D. (mm)
Roll
Color
Fluid
Note 1)
Max. operating temperature (fixed usage)
Material
Max. operating
pressure (MPa)
Min. bending
radius (mm)
Note 3)
Applicable fittings
Note 2)
10 m
20 m
20°C
100°C
200°C
260°C
Recommended radius
Refraction value
4
2.5
1.6
0.9
0.45
0.23
15
8
1.4
0.7
0.35
0.2
25
16
0.9
0.5
0.25
0.15
45
31
0.9
0.5
0.25
0.15
55
35
0.9
0.5
0.25
0.15
75
41
TD0604
6
4
TD0806
8
6
Translucent (material colour)
Air, Water, Inert gas
260°C
Denatured PTFE (Polytetrafluoroethylene resin)
TD1075
10
7.5
TD1209
12
9
TD0425
Tubing model
10
Length per roll
Symbol
10
20
Length
10 m roll
20 m roll
Metric size
Bend the tube into the U-form at
a temperature of 20°C. Fix one
end and close loop gradually.
Measure
2R when the deformed
ratio of the tube diameter at ben-
ding reaches 5%.
How to measure the
minimum bending radius
Fixed end
2R
–20 0 20 40 60 80
100 120 140 160 180 200 220 240 260 280 300
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
Operating temperature (°C)
Max. operating pressure (MPa)
TD0425
TD0604
TD0806/TD1075/TD1209
How to Order
Maximum Operating Pressure
Soft Fluoropolymer Tubing
Inch Size
Series TID
Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the sur-
ge pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubes.
Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tube burs-
ting.
Note 2) Do not use this product in a manner in which the tube is not fixed.
Observe the lesser value of the maximum operating pressure between the tube and fitting.
A material change over a long duration or due to high-temperature may cause leakage. Perform periodic
maintenance and replace with a new product immediately when abnormalities are detected.
Refer to the “Maintenance” precautions in the TD/TID tubing.
For other precautions, see the “Fittings & Tubing” precautions in the “Best Pneumatics" catalogue.
When using the fluoropolymer fittings, please refer to the precautions in the relevant catalogue
CAT. ES70-17.
Note 3) The minimum bending radius is the representative value measured as shown below.
• Use a tube above the recommended minimum bending radius.
• The tube may be bent if used under the recommended minimum bending radius. Therefore, refer to
the refraction value and make sure that the tube is not bent or flattened.
• Please note that the refraction value is not warranted because of the value when 2R is measured by
the method shown above on the left if the tube is bent or flattened, etc.
TID01
Tubing model
8
Length per roll
Inch size
Bend the tube into the U-form at
a temperature of 20°C. Fix one
end and close loop gradually.
Measure
2R when the deformed
ratio of the tube diameter at ben-
ding reaches 5%.
2R
–20 0 20 40 60 80
100 120 140 160 180 200 220 240 260 280 300
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
Operating temperature (°C)
Max. operating pressure (MPa)
TID07
TID01/TID05/TID11
TID13
Length
25 ft (8 m) roll
50 ft (16 m) roll
Symbol
8
16
Model/Specifications
Inch size
Model
Size
TID01
Tubing O.D.
Tubing I.D.
Roll
Color
Fluid
Note 1)
Applicable fittings
Note 2)
Max. operating temperature (fixed usage)
Material
inch
mm
inch
mm
8 m
16 m
1/8"
3.18
0.086"
2.18
1.4
0.7
0.35
0.2
15
9
TID05
3/16"
4.75
3.15
1.4
0.7
0.35
0.2
20
10
0.124"
(1/8")
0.156"
(5/32")
0.25"
(1/4")
0.374"
(3/8")
TID07
1/4"
6.35
3.95
1.6
0.9
0.45
0.23
25
15
260°C
Denatured PTFE (Polytetrafluoroethylene resin)
TID11
3/8"
9.53
6.33
1.4
0.7
0.35
0.2
40
23
TID13
1/2"
12.7
9.5
0.9
0.5
0.25
0.15
75
42
Max. operating
pressure (MPa)
Min. bending
radius (mm)
Note 3)
Recommended radius
Refraction value
Translucent (material colour)
Air, Water, Inert gas
Fluoropolymer fitting LQ2 series
20°C
100°C
200°C
260°C
How to measure the
minimum bending radius
Fixed end
2