Datasheet

Series V100 3 Port Solenoid Valve
Valves
Page 234
Specifications
Fluid
Ambient and fluid temperature (°C)
Response time (ms)
Max. operating frequency (Hz)
Lubrication
Mounting position
Air
–10 to 50 No freezing
ON: 5 or less OFF: 4 or less
20
Not required
Unrestricted
Elerctrical Specifications
Electrical entry
Coil rated voltage (V)
DC
Indicator light
Power consumption
(W)
DC
24, 12, 6, 5, 3
–10 to 10%
Grommet (G)/(H), L plug connector(L)
M plug connector (M)
Allowable voltage fluctuation
Series
V114/V124
Standard: 0.35
(With indicator light: 0.4)
With power saving circuit 0.1
V114A/V124A
Manual override
Non-locking push, Locking slotted
1 W (With indicator light: 1.1)
LED
Pressure Specifications
Valve
model
Valve
model
Grommet
L plug connector
M plug connector
Plug connector
Weight (g)
with sub-plate)
Operating
pressure
range (MPa)
Vacuum specification (MPa)
Port size
0 to 0.7
0 to 0.7
0 to 0.7
0 to 0.7
N.C.
N.C.
N.O.
N.O.
V114
V114A
V124
V124A
–100 kPa to 0.6
–100 kPa to 0.6
–100 kPa to 0
–100 kPa to 0
–100 kPa to 0
–100 kPa to 0
–100 kPa to 0.6
–100 kPa to 0.6
M5
M5
M5
M5
M5
M5
M5
M5
Port 1 Port 3 Port 1, 3 Port 2
V1
4: 27
V1
4A: 30
V1
4: 26
V1
4A: 29
Model
Standard
Large flow capacity
Standard
Large flow capacity
1
2
Flow characteristics
2
3
V114
V114A
V124
V124A
C
[
dm
3
/
(
s
bar
)]
0.037
0.076
0.054
0.099
b
0.11
0.070
0.35
0.23
Cv
0.0080
0.016
0.015
0.024
C
[
dm
3
/
(
s
bar
)]
0.054
0.099
0.037
0.076
b
0.35
0.23
0.11
0.070
Cv
0.015
0.024
0.0080
0.016
Type of
actuation
Manifold
Port size
1, 2, 3 port
Type VV100-S41
V114
V114A
V124
V124A
M5
Note) Values when manifold base (5 stations) is mounted.
1
2
Flow characteristics
2
3
C
[
dm
3
/
(
s
bar
)]
0.032
0.070
0.050
0.085
b
0.13
0.10
0.26
0.16
Cv
0.0072
0.016
0.012
0.020
C
[
dm
3
/
(
s
bar
)]
0.050
0.085
0.032
0.070
b
0.26
0.16
0.13
0.10
Cv
0.012
0.020
0.0072
0.016
Flow Specifications
On single sub-plate