CAT.ES70-20 A Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air Series VDW VDW10/20/30: 2 Port, VDW200/300: 3 Port Compact/Light weight (compared to series VX) Single valve volume: Reduced 75% (VDW20) 100g: Reduced approx.
Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air SeriesVDW Compact (compared to series VX) Single valve volume: Reduced 75% (VDW20) Manifold length: Reduced 18% (VDW30, 7 stations) Light weight (compared series VX) 100g: Reduced approx.
Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 How to Order Valves (Single Type) VD W 2 1 1 G 2 01 For water, air and vacuum Option Series 1 2 3 10 20 30 Nil F None Foot type bracket Note) Foot brackets are packed with valves. Materials and insulation type Valve type Symbol Body material Seal material Coil insulation NBR Nil Brass FKM A Class B NBR G Stainless FKM H steel FKM L Note) N.C.
Series VDW10/20/30 Standard Specifications Valve specifications Valve construction Direct operated poppet Fluid Note 2) Water (except waste water or agricultural water), Air, Low vacuum Withstand pressure MPa 2.
Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 Construction VDW11 VDW21 VDW31 Parts list Description No.
Series VDW10/20/30 Dimensions VDW11 VDW21 22 20 Lead wire l approx. 300 27 20 27 21 Lead wire l approx. 300 Rectifying device AC type 2–ø3.5 14 2– ø3.2 20 20 27 Rectifying device AC type ø20.5 48 54 ø17 1 5 5 8 6 1 M5 1 (IN) port M5, 1/8 M5, 1/8 2 (OUT) port 1 (IN) port 15 11 M5 2 (OUT) port 2-M2.5 x 0.45 Thread depth 3.5 2-M3 x 0.5 Thread depth 5 VDW31 36 (27.6) 1 1 SMC SMC 40 30 Lead wire l approx.
Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 How to Order Manifolds VV2DW 2 How to Order Manifold Assemblies (Example) 05 01 Series 1 2 3 Enter the valve and option models to be mounted under the manifold base part number. VV2DW2-0501 ……... 1 set Manifold part no. Option 10 20 30 None With bracket Nil F Note) Type 30 is available only with bracket.
Series VDW10/20/30 Dimensions (1.5) 8.8 8.8 2.8 13.4 24.4 34 16.3 (2.8) 30 3.4 1 9.4 (4.4) 7 1. R Approx. 300 16 (19.6) VV2DW1 P = 17.5 2-∗1/8 (IN port) (∗: Thread type) L1 L2 L3 1 Stations 2 VDW13-*G-* VDW13-*G-* 3 4 VDW13-*G-* VDW13-*G-* U side n 5 7.7 P = 17.5 26.5 1.5 13 61 n-M5 x 0.8 (OUT port) 19.6 D side 8.1 4-M3 x 0.5 11.5 11.5 7.7 7.7 (16.3) ∗ When not equipped with bracket, the M3 threads at both ends (4 positions) can be used for other purposes.
Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 Dimensions 15 ( 25.5) VV2DW2 9 L1 (∗: Thread type) L2 33 4.6 2-∗1/4 (IN port) .3 R2 4.5 24 (19.5) 16 19.5 1 11 Approx. 300 1 L3 Stations 1 2 3 4 VDW23-*G-* VDW23-*G-* VDW23-*G-* VDW23-*G-* n 5 U side 11 32 54 6 10 24 46 10 21 4.5 9.5 11 11 6 1.5 n-M5 x 0.8 n-∗1/8 (OUT port) P = 22 9.5 ( 19.5) 11 31.5 18.5 68 D side 4-M4 x 0.
Series VDW10/20/30 Dimensions 23 (26.5) VV2DW3 10.5 4.5 28 38 (24.5) 5 .2 R2 5.5 20 24.5 49 14.7 Approx. 300 2.5 L1 L2 L3 2-∗3/8 (IN port) (∗: Thread type) D side Stations 1 2 VDW33-*G-* 4 VDW33-*G-* 5 U side n VDW33-*G-* 17.25 5.5 n-∗1/8 n-∗1/4 (OUT port) P = 34.5 17.25 2 16 21 34 83 VDW33-*G-* 3 L dimensions Dimensions (mm) n (stations) 2 3 4 5 6 7 8 9 10 L1 69 103.5 138 172.5 207 241.5 276 310.5 345 L2 81 115.5 150 184.5 219 253.5 288 322.
Compact Direct Operated 2 Port Solenoid Valve for Water and Air Series VDW10/20/30 Manifold Exploded View Bracket assembly 2 station manifold base Passage pipe assembly 3 station manifold base Bracket assembly Connecting plate assembly Connecting plate assembly ∗ Figure shows VV2DW2. Manifold additions 1 Install a passage pipe assembly in between the manifold bases to be added. 2 Connect the respective manifold bases with a connecting plate assembly. (Tightening torque: 0.9±0.
Series VDW10/20/30 Types Note) Two sets of connecting plate and mounting screws. 10, 20 VVDW 2 0 2 C 1 Types 01 10, 20 VVDW 2 0 4A Series 1 2 10 20 Series Thread type Rc G NPT Nil Material F N Brass Stainless steel C S OUT port size Stations Symbol M5 01 For 2 stations For 3 stations 1 2 Port size M5 1/8 (6A) 1 2 Type 10 20 30 VVCW20-4A ∗ Type 10 is M5 only.
Compact Direct Operated 3 Port Solenoid Valve for Water and Air Series VDW200/300 How to Order Valves (Single Type) VD W 2 50 1 G 2 01 For water, air and vacuum Series 2 3 Option 200 300 Nil F None Foot type bracket Note) Foot brackets are packed with valves. Materials and insulation type Valve type Symbol Body material Seal material Coil insulation Nil NBR Brass A FKM Class B G NBR Stainless H FKM steel L Note) FKM C.O. N.C. N.O.
Series VDW200/300 Standard Specifications Direct operated poppet Valve specifications Valve construction Fluid Note 2) Water (except waste water or agricultural water), Air, Low vacuum Withstand pressure MPa 2.
Compact Direct Operated 3 Port Solenoid Valve for Water and Air Series VDW200/300 Construction VDW250 VDW350 Parts list Description No.
Series VDW200/300 Dimensions VDW250 VDW350 36 (27.6) 22 Lead wire l approx. 300 27 20 Lead wire l approx. 300 Rectifying device AC type M5, 1/8 3 (N.O.) port ø20.5 25 34 4–ø5 1/8, 1/4 3 (N.O.) port 1 1 40 30 20 27 SMC SMC 2–ø3.5 Rectifying device AC type ø28 3 5 8 1 8.5 (6.3) M5, 1/8 1 (IN) port 15 6 M5, 1/8 2 (N.C.) port 86 (82.5) 69 3 1/8, 1/4 1 (IN) port 1/8, 1/4 2 (N.C.) port 2-M3 Thread depth 5 12.8 Dimensions inside ( ) are for port size 1/8. 2-M4 x 0.
Series VDW Model Selection Downstream pressure of valve (P2) MPa For air Explanation of Terminology Upstr eam press ure o f 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.05 VDW10ø1 VDW10 20 ø1.6 VDW20ø2.3 0.1 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0.6 0.55 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 10 20 30 50 50 VDW20ø3.2 VDW30ø2 VDW30ø3 VDW30ø4 100 100 1. Maximum operating pressure differential Sonic 50 100 200 S = 1.2 125 250 400 S = 0.54 60 300 500 S = 3.2 350 S = 5.8 600 S = 2.
Series VDW Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by a label of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1) and other safety practices. Caution : Operator error could result in injury or equipment damage. Warning : Operator error could result in serious injury or loss of life.
Series VDW 2/3 Port Solenoid Valve for Fluid Control/Precautions 1 Be sure to read before handling. Precautions on Design 1. Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2.
Series VDW 2/3 Port Solenoid Valve for Fluid Control/Precautions 2 Be sure to read before handling. Mounting Warning 1. If air leakage increases or equipment does not operate properly, stop operation. After mounting is completed, confirm that it has been done correctly by performing a suitable function test. 2. Do not apply external force to the coil section. When tightening is performed, apply a wrench or other tool to the outside of the piping connection parts. 3.
Series VDW 2/3 Port Solenoid Valve for Fluid Control/Precautions 3 Be sure to read before handling. Wiring Operating Environment Caution Warning 1. As a rule, use electrical wire of 0.5 to 1.25mm² or more. Furthermore, do not allow excessive force to be applied to the lines. 2. Use electrical circuits which do not generate chattering in their contacts. 3. Use voltage which is within ±10% of the rated voltage.
Series VDW/ Specific Product Precautions 1 Be sure to read before handling. Refer to pages 16 through 19 for safety instructions and precautions for 2/3 port solenoid valve for fluid control. Replacement of the Solenoid Coil Caution 2 port valve 3 port valve Socket Flat head screw driver 1 Tube assembly O-ring Clip Plate Cover Push the clip in direction (1) with Wave washer a flat head screw driver, etc., and remove it from the tube assembly groove.
Series VDW/ Specific Product Precautions 2 Be sure to read before handling. Refer to pages 16 through 19 for safety instructions and precautions for 2/3 port solenoid valve for fluid control. Replacement Parts Fluid Flow Direction Caution Solenoid coil part numbers VDW 2 0 1 2 3 1 B 1 Series Lead wire length 10 20, 200 30, 300 L1 Note) Nil The maximum operating pressure differential differs depending on the flow direction of the fluid.
SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE EUROPE NORTH AMERICA AUSTRIA SMC Pneumatik GmbH CZECH SMC Czech s.r.o. DENMARK SMC Pneumatik A/S FINLAND SMC Pneumatiikka OY FRANCE SMC Pneumatique SA GERMANY SMC Pneumatik GmbH HUNGARY SMC Hungary Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A. NETHERLANDS SMC Pnuematics BV. NORWAY SMC Pneumatics Norway A/S ROMANIA SMC Romania s.r.l. RUSSIA SMC Pneumatik LLC. SLOVAKIA SMC Slovakia s.r.o. SLOVENIA SMC Slovenia d.o.o.