Datasheet

Pressure switch
0.2
0.4
0.1
0.3
MPa
23 15
AD
C
B
(13)
(23)
(5000)
(3000)
(500)
Centre of
F.R.L. body
B
C
E
D A
Octagon
Port size
Centre of
F.R.L. body
Fluid Air
Ambient and fl uid temperature
−5 to 60°C (with no freezing)
Proof pressure 1.0 MPa
Maximum operating pressure
0.7 MPa
Set pressure range (when OFF)
0.1 to 0.4 MPa
Hysteresis 0.08 MPa or less
Contact point confi guration 1a
Maximum contact point capacity
2 VA (AC), 2 W (DC)
Operating voltage: AC, DC 100 V or less
Maximum operating current
12 V to 24 VAC, DC: 50 mA
48 VAC, DC: 40 mA
100 VAC, DC: 20 mA
Model
A B C D
Applicable model
IS10M-20-A
10.6 74.2 64.4 28
AC20l-B
IS10M-30-A
12.6 84.5 70.5 30
AC25l-B, AC30l-B
IS10M-40-A
14.6 93.3 75.3 36
AC40l-B
IS10M-50-A
16.6 97.3 77.3 44
AC40l-06-B
IS10M-60-A
22 92.5 68.5 53
AC50
l
-B, AC55
l
-B, AC60
l
-B
Symbol Description
Vq
Body size
20 30 40 50 60
Vw
Semi-standard
a
Set pressure
range
0.1 to 0.4 MPa
6
Note 1)
0.1 to 0.6 MPa
+
b
Lead wire
length
0.5 m
L
3 m
Z
5 m
+
c
Pressure unit of
the scale plate
MPa
P
MPa/psi dual scale
Model
Note)
Port size
A B C D E
Applicable model
Y110-M5-A
M5 x 0.8 11.2 19 12 14 8
AC10-A, AC10B-A
Y210-l01-A
1/8
14.6 41.8 32 28 19
AC20-B, AC20B-B
AC20C-B
Y210-l02-A
1/4
Y310-l01-A
1/8
14.6 52.7 38.7 30 19
AC25-B, AC25B-B
AC25C-B, AC30C-B
Y310-l02-A
1/4
Y410-l02-A
1/4
18.6 62 44 36 24
AC40-B, AC40B-B
AC40C-B
Y410-l03-A
3/8
Y510-l02-A
1/4
18.6 66 46 44 24
AC40-06-B, AC40B-06-B
AC40C-06-B
Y510-l03-A
3/8
Y610-l03-A
3/8
22 81 57 53 30
AC50-B, AC55-B, AC60-B,
AC50B-B, AC55B-B, AC60B-B
Y610-l04-A
1/2
T-spacer
Pressure Switch: (S)
Specifi cations
Switch Characteristics
Note)
For detailed specifi cations on the IS10 series, refer to the section of our
website IS10 series, http://www.smc.eu
A compact integrated pressure switch can be easily installed and facilitates the pressure detection of the line.
Using a T-spacer facilitates the branching of air fl ow.
30IS10M A
q w
T-Spacer: (T) M5 x 0.8, 1/8, 1/4, 3/8, 1/2
Caution on Mounting
Note) l in model numbers indicates a pipe thread type. No indication is necessary
for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Refer to the attachment table on page 34 for standard port sizes when using
with the AC.
If a T-spacer is used on the inlet side of the lubricator, lubricant may
be mixed. Use the AKM series check valve to avoid such possibility.
Symbol
• Semi-standard: Select one each for a to c.
• Semi-standard symbol: When more than one specifi cation is required, indicate in alphanumeric order.
Example) IS10M-30-6LP
Note 1) Set pressure range of 6P (L, Z) is 0.2 to 0.6 MPa (30 to 90 psi).
Separate spacers are required for modular unit.
35