AC40A
AC20A
Standard Specifications
Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch (AC20A to AC60A).
Note 2) –5 to 50°C for the products with the digital pressure switch
Note 3) Not applicable to the AC10A.
+
+
+
Air
–5 to 60°C (with no freezing)
1.5 MPa
1.0 MPa
Set pressure + 0.05 MPa
Note 3)
[at relief flow rate of 0.1 l/min (ANR)]
5 µm
Class 1 turbine oil (ISO VG32)
Polycarbonate
Relieving type
Semi-standard
0.59
Standard
0.05 to 0.85 MPa
0.75 1.41 1.46 3.33 3.40
Model
Component
Port size
Pressure gauge port size
Note 1)
Fluid
Ambient and fluid temperature
Note 2)
Proof pressure
Maximum operating pressure
Set pressure range
Relief pressure
Nominal filtration rating
Recommended lubricant
Bowl material
Bowl guard
Regulator construction
Mass (kg)
Filter regulator
Lubricator
1/8 1/4
AC60A
AW60
AL60
1
AC50A
AW60
AL50
3/4, 1
AC40A-06
AW40-06
AL40-06
3/4
AC40A
AW40
AL40
1/4, 3/8, 1/2
AC30A
AW30
AL30
1/4, 3/8
AC20A
AW20
AL20
1/8, 1/4
AC10A
AW10
AL10
M5 x 0.8
1/16
0.05 to 0.7 MPa
0.20
Note 1) Drain guide is NPT1/8 (applicable to the AC20A)
and NPT1/4 (applicable to the AC30A to AC60A).
The auto drain port comes with ø3/8" one-touch
fitting (applicable to the AC30A to AC60A).
Note 2) Drain guide is G1/8 (applicable to the AC20A)
and G1/4 (applicable to the AC30A to AC60A).
Note 3) Option G, M are not assembled and supplied
loose at the time of shipment.
Note 4) Not available with piping port size: 06.
Note 5) The bracket position varies depending on the
pressure switch mounting.
Note 6) The only difference from the standard
specifications is the adjusting spring for the
regulator. It does not restrict the setting of 0.2
MPa or more. When the pressure gauge is
attached, a 0.2 MPa pressure gauge will be fitted.
Note 7) Refer to Chemical Data on page 287 when
selecting a case material.
Note 8) Float type auto drain: The combination of C and D
is not possible.
Note 9) Without a valve function
Note 10) Metal bowl: The combination of 2 and 8 is not
possible.
Note 11) For thread type: M5 and NPT. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is provided
for use in Japan.) The digital pressure switch will
be equipped with the unit conversion function,
setting to psi initially.
MPa and psi are shown together on the pressure
unit.
Note 12) For options: E1, E2, E3, E4. This product is for
overseas use only according to the new
Measurement Law. (The SI unit is provided for
use in Japan.)
Note 13)
: For thread type: M5 and NPT only
Note 14)
: Select with options: E1, E2, E3, E4.
Nil
3
Lubricator
lubricant
exhaust port
i
Without drain cock
Lubricator with drain cock
Nil
N
Exhaust
mechanism
j
Relieving type
Non-relieving type
Nil
R
Flow direction
k
Flow direction: Left to right
Flow direction: Right to left
Nil
Z
Note 11)
ZA
Note 12)
Pressure unit
l
Name plate and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Digital pressure switch: With unit conversion function
Semi-standard
Description
Symbol
Note 13) Note 13) Note 13) Note 13) Note 13) Note 13)
Note 14) Note 14) Note 14) Note 14) Note 14)
10 20 30 40 50 60
Body size
307
Air Combination
Series AC10A to AC60A
AC
AF
AR
AL
AW
AG
AV
AF800
AF900