Brochure

Table Of Contents
AC40B
AC20B
+
+
Note 1) Drain guide is NPT1/8 (applicable to the AC20B)
and NPT1/4 (applicable to the AC25B to AC60B).
The auto drain port comes with ø3/8" one-touch
fitting (applicable to the AC25B to AC60B).
Note 2) Drain guide is G1/8 (applicable to the AC20B)
and G1/4 (applicable to the AC25B to AC60B).
Note 3) Option G, M are not assembled and supplied
loose at the time of shipment.
Note 4) The bracket position varies depending on the T-
interface or pressure switch mounting.
Note 5) The regulator is equipped with a backflow function
in this configuration. Additionally, for safety
purposes, please check that the pressure in the
outlet side is turned to the atmospheric pressure
once the pressure in the outlet side is exhausted,
by using a pressure gauge, etc.
Note 6) The only difference from the standard
specifications is the adjusting spring for the
regulator. It does not restrict the setting of 0.2
MPa or more. When the pressure gauge is
attached, a 0.2 MPa pressure gauge will be fitted.
Note 7) Refer to Chemical Data on page 287 when
selecting a case material.
Note 8) Float type auto drain: The combination of C and D
is not possible.
Note 9) Without a valve function
Note 10) Metal bowl: The combination of 2 and 8 is not
possible.
Note 11) For thread type: M5 and NPT. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is provided
for use in Japan.) The digital pressure switch will
be equipped with the unit conversion function,
setting to psi initially.
MPa and psi are shown together on the pressure
unit.
Note 12) For options: E1, E2, E3, E4. This product is for
overseas use only according to the new
Measurement Law. (The SI unit is provided for
use in Japan.)
Note 13)
: For thread type: M5 and NPT only
Note 14)
: Select with options: E1, E2, E3, E4.
Standard Specifications
Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch (AC10B to AC60B).
Note 2) –5 to 50°C for the products with the digital pressure switch
Note 3) Not applicable to the AC10B.
Air
–5 to 60°C (with no freezing)
1.5 MPa
1.0 MPa
Set pressure + 0.05 MPa
Note 3)
[at relief flow rate of 0.1 l/min (ANR)]
5 µm
Polycarbonate
Relieving type
Semi-standard
0.51
Standard
0.55 0.63 1.12 1.16 2.542.44 2.45
Model
Component
Port size
Pressure gauge port size
Note 1)
Fluid
Ambient and fluid temperature
Note 2)
Proof pressure
Maximum operating pressure
Set pressure range
Relief pressure
Nominal filtration rating
Bowl material
Bowl guard
Regulator construction
Mass (kg)
Air filter
Regulator
AC25B
AF30
AR25
1/4, 3/8
AC30B
AF30
AR30
1/4, 3/8
AC40B
AF40
AR40
1/4, 3/8, 1/2
AC40B-06
AF40-06
AR40-06
3/4
AC50B
AF50
AR50
3/4, 1
AC55B
AF60
AR50
1
AC60B
AF60
AR60
1
AC20B
AF20
AR20
1/8, 1/4
AC10B
AF10
AR10
M5 x 0.8
1/16
0.05 to 0.7 MPa
0.16
1/8 1/4
0.05 to 0.85 MPa
Nil
N
Exhaust
mechanism
h
Relieving type
Non-relieving type
Nil
R
Flow direction
i
Flow direction: Left to right
Flow direction: Right to left
Nil
Z
Note 11)
ZA
Note 12)
Pressure unit
j
Name plate and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Digital pressure switch: With unit conversion function
10 20 25 30 40 50 55 60
Body size
Description
Symbol
Semi-standard
Note 13) Note 13) Note 13) Note 13) Note 13) Note 13)
Note 14) Note 14)
Note 13)
Note 14) Note 14) Note 14)
Note 13)
Note 14) Note 14)
311
Air Combination
Series AC10B to AC60B
AC
AF
AR
AL
AW
AG
AV
AF800
AF900