Brochure

Table Of Contents
AC20D AC40D
Nil
Z
Note 11)
ZA
Note 12)
Pressure unit
Name plate and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Digital pressure switch: With unit conversion function
j
Semi-
standard
Description
Symbol
30 4020
Body size
Note 13) Note 13)Note 13)
Note 14) Note 14)Note 14)
Air
–5 to 60°C (with no freezing)
1.5 MPa
1.0 MPa
0.05 MPa
0.05 to 0.85 MPa
Set pressure + 0.05 MPa [at relief flow rate of 0.1
l/min (ANR)]
AF: 5 µm, AFM: 0.3 µm (99.9% filtered particle size)
Max. 1.0 mg/m
3
(ANR) ( 0.8 ppm)
Note 4) Note 5)
Polycarbonate
Relieving type
330
0.74
150
Semi-standard
0.57
800
Standard
1.38
800
1.43
Model
Component
Port size
Pressure gauge port size
Note 1)
Fluid
Ambient and fluid temperature
Note 2)
Proof pressure
Maximum operating pressure
Minimum operating pressure
Set pressure range
Relief pressure
Nominal filtration rating
Rated flow (l/min (ANR))
Note 3)
Outlet side oil mist concentration
Bowl material
Bowl guard
Regulator construction
Mass (kg)
Filter regulator
Mist separator
AC40D-06
AW40-06
AFM40-06
3/4
AC40D
AW40
AFM40
1/4, 3/8, 1/2
AC30D
AW30
AFM30
1/4, 3/8
AC20D
AW20
AFM20
1/8, 1/4
1/8 1/4
Standard Specifications
Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch (AC20D to AC40D).
Note 2) –5 to 50°C for the products with the digital pressure switch
Note 3) Conditions: Mist separator inlet pressure: 0.5 MPa; The rated flow varies depending on the inlet pressure. Keep the air flow within the rated flow to prevent an outflow of
lubricant to the outlet side.
Note 4) When the compressor oil mist discharge concentration is 30 mg/m
3
(ANR).
Note 5) Bowl O-ring and other O-rings are slightly lubricated.
Note 1) Drain guide is NPT1/8 (applicable to the AC20D)
and NPT1/4 (applicable to the AC30D to AC40D).
The auto drain port comes with ø3/8" one-touch
fitting (applicable to the AC30D to AC40D).
Note 2) Drain guide is G1/8 (applicable to the AC20D)
and G1/4 (applicable to the AC30D to AC40D).
Note 3) Option G, M are not assembled and supplied
loose at the time of shipment.
Note 4) The bracket position varies depending on the
pressure switch mounting.
Note 10) Metal bowl: The combination of 2 and 8 is not
possible.
Note 11) For thread type: NPT. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is provided
for use in Japan.) The digital pressure switch will
be equipped with the unit conversion function,
setting to psi initially.
MPa and psi are shown together on the pressure
unit.
Note 12) For options: E1, E2, E3, E4. This product is for
overseas use only according to the new
Measurement Law. (The SI unit is provided for
use in Japan.)
Note 13)
: For thread type: NPT only
Note 14)
: Select with options: E1, E2, E3, E4.
Note 5) The regulator is equipped with a backflow function
in this configuration. Additionally, for safety
purposes, please check that the pressure in the
outlet side is turned to the atmospheric pressure
once the pressure in the outlet side is exhausted,
by using a pressure gauge, etc.
Note 6) The only difference from the standard
specifications is the adjusting spring for the
regulator. It does not restrict the setting of 0.2
MPa or more. When the pressure gauge is
attached, a 0.2 MPa pressure gauge will be fitted.
Note 7) Refer to Chemical Data on page 287 when
selecting a case material.
Note 8) Float type auto drain: The combination of C and D
is not possible.
Note 9) Without a valve function
319
Air Combination
Series AC20D to AC40D
AC
AF
AR
AL
AW
AG
AV
AF800