Brochure

Table Of Contents
D
B
C
A
30IS1000M
B
C
E
DA
A compact integrated pressure switch can be easily installed and facilitates the pressure detection of the line.
Pressure Switch: (S)
Pressure switch
JIS Symbol
Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)
Body size
Description
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
MPa
MPa/psi dual scale
MPa
MPa/psi dual scale
MPa
MPa/psi dual scale
MPa
MPa/psi dual scale
0.5 m
0.5 m
0.5 m
0.5 m
3 m
3 m
3 m
3 m
Set pressure
range
Pressure displayLead wire length
Symbol
Nil
P
Note)
X202
X202-P
Note)
X201
X201-P
Note)
X215
X215-P
Note)
Option
20
30 40 50 60
15
500
23
Center of
F.R.L. body
IS1000M-20
IS1000M-30
IS1000M-40
IS1000M-50
IS1000M-60
Model
AC20
AC25, AC30
AC40
AC40-06
AC50, AC55, AC60
Applicable model
A
11
13
15
17
22
B
76
86
95
99
92.5
C
66
72
77
79
68.5
D
28
30
36
44
53
Note) Separate spacers are required for modular unit.
Using a T-interface facilitates the redirection of air flow.
T-interface: (T) M5 x 0.8, 1/8, 1/4, 3/8, 1/2
Specifications
Fluid
Ambient and fluid temperature
Proof pressure
Maximum operating pressure
Set pressure range (when OFF)
Hysteresis
Air
–5 to 60°C (with no freezing)
1.0 MPa
0.7 MPa
0.1 to 0.4 MPa
0.08 MPa or less
Switch Characteristics
Contact point configuration
Maximum contact point capacity
Operating voltage: AC, DC
Maximum operating current
1a
2 VA (AC), 2 W (DC)
100 V or less
12 V to 24 VAC, DC: 50 mA
48 VAC, DC: 40 mA
100 VAC, DC: 20 mA
Note) For detailed specifications on the IS1000 series, please refer to series IS1000 in
Best Pneumatics No.6.
Octagon
Port size
Center of
F.R.L. body
T-interface
Caution on Mounting
If a T-interface is used on the IN side of the lubricator, lubricant
may be mixed. Use the AKM series check valve to avoid such
possibility.
AC10, AC10B
AC20, AC20B,
AC20C
AC25, AC25B,
AC25C, AC30,
AC30B, AC30C
AC40, AC40B,
AC40C
AC40-06, AC40B-06
AC40C-06
AC50, AC55,
AC60, AC50B,
AC55B, AC60B
Applicable model
Y110-M5
Y210-01
Y210-02
Y310-01
Y310-02
Y410-02
Y410-03
Y510-02
Y510-03
Y610-03
Y610-04
Port size
M5 x 0.8
1/8
1/4
1/8
1/4
1/4
3/8
1/4
3/8
3/8
1/2
Model
Note 1) in model numbers indicates a thread type. No indication is necessary for Rc;
however, indicate N for NPT, and F for G.
Note 2) Separate interfaces are required for modular unit.
Refer to the attachment table on page 321 for standard port sizes when using with the AC.
C
12
32
39
44
46
57
D
14
28
30
36
44
53
E
8
19
19
24
24
30
B
19
42
53
62
66
81
A
11
15
15
19
19
22
322
Series AC