Brochure

Table Of Contents
B
D
A
Piping adapter
IS1000E
30 03
D
B
C
A
E
A piping adapter allows
installation/removal of the
component without removing
the piping and thus makes
maintenance easier.
Piping Adapter: M5 x 0.8, 1/8, 1/4, 3/8, 1/2, 3/4, 1
Center of
F.R.L. body
Port size
Applicable model
AC10, AW10, AF10, AR10, AL10
AC20
AF20, AR20, AW20
AL20, AFM20, AFD20, AWM20, AWD20
AC25, AC30
AF30, AR30, AW30
AL30, AFM30, AFD30, AWM30, AWD30
AC40
AF40, AR40, AW40
AL40, AFM40, AFD40
AWM40, AWD40
AC40-06, AF40-06, AR40-06,
AW40-06, AL40-06,
AFM40-06, AFD40-06
Port size
M5 x 0.8
1/8
1/4
3/8
1/4
3/8
1/2
1/4
3/8
1/2
3/4
3/4
3/4
1
Note 1) in model numbers indicates a thread type. No indication is necessary for Rc;
however, indicate N for NPT, and F for G.
Note 2) Separate interfaces are required for modular unit.
Factory mounting of a piping adapter on the AC models is available as a special order.
D
14
28
30
36
44
53
B
14
23.5
30
36
40
48
A
10
30
32
32
32
35
Model
Note 1)
E100-M5
E200-01
E200-02
E200-03
E300-02
E300-03
E300-04
E400-02
E400-03
E400-04
E400-06
E500-06
E600-06
E600-10
AC50, AC55, AC60, AC50A
AC60A, AC50B, AC55B
AC60B, AF50, AF60, AR50
AR60, AL50, AL60, AW60
Pressure Switch with Piping Adapter
JIS Symbol
Pressure switch with
piping adapter
Left Right
500
23
Center of
F.R.L. body
Port size
Note 1) in the model numbers indicates a thread type. No indication is necessary for Rc; however,
indicate N for NPT, and F for G.
Note 2) Cannot be mounted on the AC40-06 and AW40-06.
Note 3) Separate interfaces are required for modular unit.
The pressure switch on the AC40-06 and above and the AW40-06 can be mounted by screwing IS1000-01 into
the piping adapter E500-06-X501 or E600-06-X501 to E600-10-X501 (with top-face thread Rc 1/8). Products
with a premounted switch are available as a special order. Please contact SMC regarding their availability.
Model
Note 1)
IS1000E-2001
IS1000E-2002
IS1000E-2003
IS1000E-3002
IS1000E-3003
IS1000E-3004
IS1000E-4002
IS1000E-4003
IS1000E-4004
IS1000E-4006
Port size
1/8
1/4
3/8
1/4
3/8
1/2
1/4
3/8
1/2
3/4
Applicable model
Note 2)
AC40
AR40, AW40
AWM40, AWD40
A
30
32
32
B
68
74.5
80.5
C
57
60.5
62.5
D
28
30
37
E
16
13
12.5
AC20
AR20, AW20
AWM20, AWD20
AC25, AC30
AR25, AR30, AW30
AWM30, AWD30
Specifications
Switch Characteristics
Fluid
Ambient and fluid temperature
Proof pressure
Maximum operating pressure
Set pressure range (when OFF)
Hysteresis
Air
–5 to 60°C (with no freezing)
1.0 MPa
0.7 MPa
0.1 to 0.4 MPa
0.08 MPa or less
Contact point configuration
Maximum contact point capacity
Operating voltage: AC, DC
Maximum operating current
1a
2VA(AC), 2W(DC)
100V or less
12V to 24V AC, DC: 50 mA
48V AC, DC: 40 mA
100V AC, DC: 20 mA
Note) For thread type: NPT only. This product is for overseas use only according to the new Measurement Law.
(The SI unit type is provided for use in Japan.)
+
+
Body size
DescriptionSymbol
Nil
N
Note)
F
Note)
Thread type
Rc
NPT
G
01
02
03
04
06
Port size
1/8
1/4
3/8
1/2
3/4
20
30 40
MPa
MPa
MPa/psi dual scale
MPa/psi dual scale
MPa
MPa
MPa/psi dual scale
MPa/psi dual scale
MPa
MPa
MPa/psi dual scale
MPa/psi dual scale
MPa
MPa
MPa/psi dual scale
MPa/psi dual scale
Right
Left
Right
Left
Right
Left
Right
Left
Right
Left
Right
Left
Right
Left
Right
Left
0.5 m
0.5 m
0.5 m
0.5 m
0.5 m
0.5 m
0.5 m
0.5 m
3 m
3 m
3 m
3 m
3 m
3 m
3 m
3 m
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.4 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
0.1 to 0.6 MPa
Accessory
Regulating pressure range
Pressure display
Lead wire lengthSymbol
Mounting position
Nil
X250
P
Note)
X250-P
Note)
X202
X252
X202-P
Note)
X252-P
Note)
X201
X251
X201-P
Note)
X251-P
Note)
X215
X253
X215-P
Note)
X253-P
Note)
324
Series AC