Brochure

Table Of Contents
AC40AC20
Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch (AC20 to AC60).
Note 2) –5 to 50°C for the products with the digital pressure switch
Note 3) Not applicable to the AC10.
Air
–5 to 60°C (with no freezing)
1.5 MPa
1.0 MPa
Set pressure + 0.05 MPa
Note 3)
[at relief flow rate of 0.1 l/min (ANR)]
5 µm
Class 1 turbine oil (ISO VG32)
Polycarbonate
Relieving type
0.05 to 0.7 MPa
0.05 to 0.85 MPa
AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60
AF10
AR10
AL10
M5 x 0.8
1/16
1/8, 1/4 1/4, 3/8
1/8
1/4, 3/8
1/4, 3/8, 1/2
3/4 3/4, 1
1/4
11
0.27
Semi-standard
0.73 0.91 1.00 1.74
Standard
1.95 4.17 4.25 4.34
AF20
AR20
AL20
AF30
AR25
AL30
AF30
AR30
AL30
AF40
AR40
AL40
AF40-06
AR40-06
AL40-06
AF50
AR50
AL50
AF60
AR50
AL60
AF60
AR60
AL60
Model
Component
Air filter
Regulator
Lubricator
Port size
Pressure gauge port size
Note 1)
Fluid
Ambient and fluid temperature
Note 2)
Proof pressure
Max. operating pressure
Set pressure range
Relief pressure
Nominal filtration rating
Recommended lubricant
Bowl material
Bowl guard
Regulator construction
Mass (kg)
Standard Specifications
+
+
+
+
Note 1) Drain guide is NPT1/8 (applicable to the AC20)
and NPT1/4 (applicable to the AC25 to AC60).
The auto drain port comes with ø3/8" one-touch
fitting (applicable to the AC25 to AC60).
Note 2) Drain guide is G1/8 (applicable to the AC20) and
G1/4 (applicable to the AC25 to AC60).
Note 3) Option G, M are not assembled and supplied
loose at the time of shipment.
Note 4) Not available with piping port size: 06.
Note 5) The bracket position varies depending on the T-
interface or pressure switch mounting.
Note 6) The only difference from the standard
specifications is the adjusting spring for the
regulator. It does not restrict the setting of 0.2
MPa or more. When the pressure gauge is
attached, a 0.2 MPa pressure gauge will be fitted.
Note 7) Refer to Chemical Data on page 287 when
selecting a case material.
Note 8) Float type auto drain: The combination of C and D
is not possible.
Note 9) Without a valve function
Note 10) Metal bowl: The combination of 2 and 8 is not
possible.
Note 11) Filter drain port: When choosing with W, the
drain cock of a lubricator will be with barb fittings.
Note 12) For thread type: M5 and NPT. This product is for
overseas use only according to the new
Measurement Law. (The SI unit type is provided
for use in Japan.) The digital pressure switch will
be equipped with the unit conversion function,
setting to psi initially.
MPa and psi are shown together on the pressure
unit.
Note 13) For options: E1, E2, E3, E4. This product is for
overseas use only according to the new
Measurement Law. (The SI unit is provided for
use in Japan.)
Note 14)
: For thread type: M5 and NPT only
Note 15)
: Select with options: E1, E2, E3, E4.
Nil
3
Note 11)
Lubricator
lubricant
exhaust port
j
Without drain cock
Lubricator with drain cock
Nil
N
Exhaust
mechanism
k
Relieving type
Non-relieving type
Nil
R
Flow direction
l
Flow direction: Left to right
Flow direction: Right to left
Note 14) Note 14) Note 14) Note 14) Note 14) Note 14) Note 14) Note 14)
Note 15) Note 15) Note 15) Note 15) Note 15) Note 15) Note 15)
Nil
Z
Note 12)
ZA
Note 13)
Pressure unit
m
Name plate and pressure gauge in imperial units: MPa
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Digital pressure switch: With unit conversion function
Nil
J
Note 9)
W
Note 10)
Filter
drain port
Note 8)
i
With drain cock
Drain guide 1/8
Drain guide 1/4
Drain cock with barb fitting: For ø6 x ø4 nylon tube
10 20 25 30 40 50 55 60
Body size
Description
Symbol
Semi-standard
301
Air Combination
Series AC10 to AC60
AC
AF
AR
AL
AW
AG
AV
AF800
AF900