Brochure

Table Of Contents
AC30
Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa
0.6
0.5
0.4
0.3
0.2
0.1
0
0 25 50 75 100 125 150
AC10
M5 x 0.8
Outlet pressure (MPa)
Flow rate (l/min (ANR))
0
0.6
0.5
0.4
0.3
0.2
0.1
0
200 400 600 800
AC20
Rc1/4
Outlet pressure (MPa)
Flow rate (l/min (ANR))
0
0.5
0.6
0.4
0.3
0.2
0.1
0
500 1000 1500
AC25
Rc3/8
Outlet pressure (MPa)
Flow rate (l/min (ANR))
0.6
0.5
0.4
0.3
0.2
0.1
0
0 1000 2000 3000 4000 5000
AC40-06
Rc3/4
Flow rate (l/min (ANR))
Outlet pressure (MPa)
0
0.6
0.5
0.4
0.3
0.2
0.1
0
AC60
Rc1
Flow rate (l/min (ANR))
Outlet pressure (MPa)
4000 6000 80002000 10000
0
0.6
0.5
0.4
0.3
0.2
0.1
0
AC55
Rc1
Flow rate (l/min (ANR))
Outlet pressure (MPa)
4000 6000 80002000 10000
0
0.6
0.5
0.4
0.3
0.2
0.1
0
1000 2000 3000
AC40
Rc1/2
Flow rate (l/min (ANR))
Outlet pressure (MPa)
0
0.6
0.5
0.4
0.3
0.2
0.1
0
500 1000 1500
AC30
Rc3/8
Flow rate (l/min (ANR))
Outlet pressure (MPa)
0
0.6
0.5
0.4
0.3
0.2
0.1
0
AC50
Rc1
Flow rate (l/min (ANR))
Outlet pressure (MPa)
4000 6000 80002000 10000
Pressure Characteristics (Representative values)
Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20
l/min (ANR)
AC10
0.25
0.3
0.2
0.15
0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa)
Outlet pressure (MPa)
Set
point
0.25
0.2
0
0.15
0
Outlet pressure (MPa)
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa)
Set
point
0.25
0.2
0
0.15
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa)
Outlet pressure (MPa)
AC40
Set
point
0.25
0.2
0
0.15
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa)
Outlet pressure (MPa)
Set
point
AC20
0.25
0.2
0
0.15
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa)
Outlet pressure (MPa)
AC25
Set
point
0.25
0.2
0
0.15
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa)
Outlet pressure (MPa)
AC40-06
Set
point
302
Series AC10 to AC60