Datasheet

28
AC
AF
AR
ALAW
ALAF
ARAF
AFM
ARAW
AFM
AF Attachment
AFM / AFD
ARALAW
Section
Model
Type
Part no.
For AC10-A For AC20-A For AC25-A For AC30-A For AC40-A For AC40-06-A
For AC10A-A For AC20A-A For AC30A-A For AC40A-A For AC40A-06-A
For AC10B-A For AC20B-A For AC25B-A For AC30B-A For AC40B-A For AC40B-06-A
For AC20C-A For AC25C-A For AC30C-A For AC40C-A For AC40C-06-A
For AC20D-A For AC30D-A For AC40D-A For AC40D-06-A
Option
Pressure gauge
Note 1)
Round
type
Standard G27-10-R1 G36-10-l01 G46-10-l01
0.02 to 0.2 MPa setting
G27-10-R1
Note 2)
G36-4-l01 G46-4-l01
Round type
(with colour
zone)
Standard G36-10-l01-L G46-10-l01-L
0.02 to 0.2 MPa setting
G36-4-l01-L G46-4-l01-L
Attachment
Spacer Y100-A Y200-A Y300-A Y400-A Y500-A
Spacer with bracket Y100T-A Y200T-A Y300T-A Y400T-A Y500T-A
Check valve
Note 3) Note 4)
AKM2000-l01-A
(l02)-A
AKM3000-(l01)-A
l02-A
AKM4000-(l02)-A
l03-A
Pressure switch
Note 4)
IS10M-20-A IS10M-30-A IS10M-40-A IS10M-50-A
T-spacer
Note 3) Note 4)
Y110-M5-A
Y210-l01-A
(l02)-A
Y310-(l01)-A
l02-A
Y410-(l02)-A
l03-A
Y510-(l02)-A
l03-A
Pressure relief
3 port valve
Note 4)
VHS20-l01A
l02A
VHS30-l02A
l03A
l02A
VHS40-l03A
l04A
VHS40-l06A
Piping adapter
Note 4)
E100-M5-A
l01-A
E200-l02-A
l03-A
l02-A
E300-l03-A
l04-A
l02-A
E400-l03-A
l04-A
l06-A
E500-l06-A
Pressure switch with
piping adapter
Note 4)
l01-A
IS10E-20l02-A
l03-A
l02-A
IS10E-30l03-A
l04-A
l02-A
IS10E-40l03-A
l04-A
l06-A
Cross spacer
Note 4)
Y14-M5-A
Y24-l01-A
l02-A
Y34-l01-A
l02-A
Y44-l02-A
l03-A
Y54-l03-A
l04-A
Check valve
A
D
B
C
E
OUT
By-pass port size for
redirecting air flow
IN
Note 1) l in round pressure gauge part numbers indicates a pipe thread type. No indication is necessary for R; however, indicate N for NPT.
Please contact SMC regarding the pipe thread type NPT and the supply of pressure gauge with psi unit display specifi cations.
Note 2) Standard pressure gauge
Note 3) For F.R.L. units, port sizes without ( ) are standard specifi cations.
Note 4) Separate interfaces are required for modular unit.
Note) Cannot be mounted on the AC40l-06-A.
Refer to the attachment table above for standard by-pass port
sizes applicable to the AC.
A check valve with intermediate air release port can be easily installed to prevent a backfl ow of lubricant when redirecting the air fl ow
and releasing the air on the outlet side of the regulator.
Check Valve: (K) 1/8, 1/4, 3/8
Specifi cations
Be sure to use above check valves when
redirecting the air fl ow on the inlet side of
the lubricator. Threads for IN and OUT
ports are not machined.
Symbol
AKM A00
30 01
q ew
Model
By-pass
port size
A B C D E
Applicable model
AKM2000-A
1/8, 1/4 40 28 11 40 11
AC20-A, AC20A-A
AKM3000-A
1/8, 1/4 53 34 14 48 13
AC25-A
AC30-A, AC30A-A
AKM4000-A
1/4, 3/8 70 42 18 54 15
AC40-A, AC40A-A
Note)
Symbol
Description
q
Body size
20 30 40
w
Pipe thread
type
Rc
V V V
N
NPT
V V V
F
G
V V V
+
e
By-pass
port size
01
1/8
V V
02
1/4
V V V
03
3/8
V
Model Effective area [mm
2
]
AKM2000-A
28
AKM3000-A
55
AKM4000-A
111
Air Combination
Series AC
Options/Attachments
Options/Attachments/Part No.