Datasheet

29
Series AC
Pressure switch
0.2
0.4
0.1
0.3
MPa
23 15
AD
C
B
(13)
(23)
(5000)
(3000)
(500)
Centre of
F.R.L. body
T-spacer
B
C
E
D A
Octagon
Port size
Centre of
F.R.L. body
Specifi cations
Switch Characteristics
Note)
For detailed specifi cations on the IS10 series, refer to the section of our
website IS10 series, http://www.smc.eu
A compact integrated pressure switch can be easily installed and facilitates the pressure detection of the line.
Using a T-spacer facilitates the branching of air fl ow.
30IS10M A
q w
Pressure Switch: (S)
T-Spacer: (T) M5 x 0.8, 1/8, 1/4, 3/8
Caution on Mounting
Note) l in model numbers indicates a pipe thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
Separate interfaces are required for modular unit.
Refer to the attachment table on page 28 for standard port sizes when using
with the AC.
If a T-spacer is used on the inlet side of the lubricator, lubricant
may be mixed. Use the AKM series check valve to avoid such
possibility.
Symbol
• Semi-standard: Select one each for a to c.
• Semi-standard symbol: When more than one specifi cation is required, indicate in alphanumeric order.
Example) IS10M-30-6LP
Note 1) Set pressure range of 6P (L, Z) is 0.2 to 0.6 MPa (30 to 90 psi).
Note 2) This product is for overseas use only according to the new Measurement Law.
(The SI unit type is provided for use in Japan.)
Separate spacers are required for modular unit.
Contact point confi guration 1a
Maximum contact point capacity
2 VA (AC), 2 W (DC)
Operating voltage: AC, DC 100 V or less
Maximum operating current
12 V to 24 VAC, DC: 50 mA
48 VAC, DC: 40 mA
100 VAC, DC: 20 mA
Symbol Description
q
Body size
20 30 40 50
w
Semi-standard
a
Set pressure
range
0.1 to 0.4 MPa
V V V V
6
Note 1)
0.1 to 0.6 MPa
V V V V
+
b
Lead wire
length
0.5 m
V V V V
L
3 m
V V V V
Z
5 m
V V V V
+
c
Pressure unit of
the scale plate
MPa
V V V V
P
Note 2)
MPa/psi dual scale
V V V V
Model
A B C D
Applicable model
IS10M-20-A
10.6 74.2 64.4 28
AC20l-A
IS10M-30-A
12.6 84.5 70.5 30
AC25l-A, AC30l-A
IS10M-40-A
14.6 93.3 75.3 36
AC40l-A
IS10M-50-A
16.6 97.3 77.3 44
AC40l-06-A
Model
Note)
Port size
A B C D E
Applicable model
Y110-M5-A
M5 x 0.8 11.2 19 12 14 8
AC10-A, AC10B-A
Y210-l01-A
1/8
14.6 41.8 32 28 19
AC20-A, AC20B-A
AC20C-A
Y210-l02-A
1/4
Y310-l01-A
1/8
14.6 52.7 38.7 30 19
AC25-A, AC25B-A
AC25C-A, AC30-A
AC30B-A, AC30C-A
Y310-l02-A
1/4
Y410-l02-A
1/4
18.6 62 44 36 24
AC40-A, AC40B-A
AC40C-A
Y410-l03-A
3/8
Y510-l02-A
1/4
18.6 66 46 44 24
AC40-06-A, AC40B-06-A
AC40C-06-A
Y510-l03-A
3/8
Fluid Air
Ambient and fl uid temperature
−5 to 60°C (with no freezing)
Proof pressure 1.0 MPa
Maximum operating pressure
0.7 MPa
Set pressure range (when OFF)
0.1 to 0.4 MPa
Hysteresis 0.08 MPa or less