Datasheet
How to Order
Suction of
workpiece
Without
workpiece
Without
workpiece
03
Fixed orifice
size (mm)
0.3
0.5
0.7
1.0
Symbol
03
05
07
10
Fixed orifice size
A5
Connection thread symbol for pad side
Applicable fixed orifice size
M5
M8
R1/8
G1/8
NPT1/8
0.3
—
—
—
—
0.5
0.7
1.0
—
Symbol
Thread
size
A5
A8
A01
AG1
AN1
Male thread connection
Applicable fixed orifice size
M5
M6
Rc1/8
G1/8
NPT1/8
0.3
—
—
—
0.5
0.7
1.0
—
—
Symbol
Thread
size
B5
B6
B01
BG1
BN1
Female thread connection
Pad side
Female
thread
Male
thread
Pad side
No.0.8
No.0.8
Vacuum Saving Valve
ZP2V
Can restrict the reduction of
vacuum pressure even when
there is no workpiece.
When multiple vacuum pads are
operated by one vacuum generator,
and some of them are not holding
the workpiece, the reduction of
vacuum pressure is restricted and
the workpiece can remain held by
the rest of pads.
No need for switching operation when
changing workpieces
When the workpieces have different shapes, the
control circuit can be simplified.
Connection thread size for pad side
Fixed orifice size (mm)
Fluid
Max. operating pressure range (MPa)
Max.
operating vacuum pressure range (kPa)
Ambient and fluid temperature (°C)
Element nominal filtration rating (µm)
Min. operating flow rate (l/min (ANR))
M5, M6
M8, R1/8, G1/8, NPT1/8
0.3 0.5 0.7
Air
0 to 0.7
0 to –100
5 to 60 (No freezing)
40
0.5 0.7 1.0
3585816
Use of ZP2V
Existing way
Valve
The operation can
be switched simply.
Only the ZP2V is
needed.
PLC
Vacuum
generator
Vacuum generator
STOP
Sensor
The sensor checks the
workpiece size, and the
valve switches the pads.
ZP2V
Vacuum
saving valve
Specifications
61