Instruction manual
Installation
183
EN
Adaptation to different types of gas
In case of operation with other types of gas, 
the burner nozzles must be changed and 
the minimum flame adjusted on the gas 
cocks.
Replacing nozzles
1. Remove the grids, burner caps and 
flame-spreader crowns to access the 
burner cups.
2. Replace the nozzles using a 7 mm 
spanner according to the gas to be 
used (see 5.2 Positioning).
3. Replace the burners in their respective 
housings.
Adjusting the minimum setting for natural 
or town gas
Light the burner and turn it to the minimum 
position. Extract the gas cock knob and turn 
the adjustment screw next to the tap rod 
(depending on the model) until the correct 
minimum flame is achieved.
Refit the knob and verify that the burner 
flame is stable. Turn the knob rapidly from 
the maximum to the minimum setting: The 
flame should not go out. Repeat the 
operation on all gas cocks.