Hood Instruction Manual

Conversion Kit
6
4)
To adjust the cooktop for LP gas or to return to
Natural Gas use, refer to the tables below.
Natural gas
Qt Injector Qr
BTU Ø mm BTU
Front Right 5200 1.10 1500
Front Left 3400 0.90 1200
Central
Inner 3000 0.85 1200
Outer 12000 1.17-1.17 4500
Rear Right 10000 1.52 2600
Rear Left 10000 1.52 2600
LP
Qt Injector Qr By-pass
BTU Ø mm BTU mm
Front Right 5200
0.65
(drw.0222)
1500 0.39
Front Left 3400
0.54
(drw.0222)
1200 0.33
Central
Inner 3000
0.50
(drw.0222)
1000 0.33
Outer 12000
0.70-0.70
(drw.0222)
4000 0.65
Rear Right 10000
0.90
(drw.0222)
2400 0.45
Front Left 10000
0.90
(drw.0222)
2400 0.45
NOTE: Save the nozzles removed from the appliance for future use.
WARNING
FIRE HAZARD
- Use a soapy solution to check for proper tightness.
- Never test for gas leaks with a match or other flames.
- Failure to follow this instruction can result in death or fire