3.2  Burner and nozzle characteristics table 
Burner 
Rated 
heating 
capacity
(kW) 
LPG – G30/G31 28/37 mbar 
Nozzle 
diameter 
1/100 mm 
By-pass 
mm 
1/100 
Reduced 
flowrate 
(W) 
Flowrate 
g/h G30 
Flowrate 
g/h G31 
Auxiliary  1.05  50  30  400  76  75 
Semi-rapid  1.8  65  33  500  131  129 
Rapid  3  85  45  800  218  215 
Triple crown  4.0  100  65  1600  290  286 
Fish pan  1.9  68  45  800  138  136 
Burner 
Rated heating 
capacity 
(kW) 
NATURAL GAS – G20 20 mbar 
Nozzle diameter 
1/100 mm 
Reduced Flowrate 
(W) 
Auxiliary  1.05  72  400 
Semi-rapid  1.8  97  500 
Rapid  3  115  800 
Triple crown  4.0  135  1600 
Fish pan  1.9  94  800 
3.3  Arrangement of burners on cooking hob 
BURNERS 
1 Auxiliary 
2 Semi rapid 
3  Rapid 
4  Ultra rapid 
5  Fish pan 