The nozzles not provided are available at Authorised Service Centres.
7 Liquid gas – G30/31 - 30/37 mbar AUX SR FB R UR2
Rated heating capacity (kW)
1.0 1.8 1.9 3.0 4.0
Nozzle diameter (1/100 mm)
50 65 68 85 100
Pre-chamber (printed on nozzle)
-----
Reduced flow rate (W)
400 500 800 800 1400
Rated flow rate G30 (g/h)
73 131 138 218 291
Rated flow rate G31 (g/h)
71 129 136 214 286
8 LPG G30/31 - 37 mbar AUX SR FB R UR2
Rated heating capacity (kW)
1.10 1.9 2.0 3.0 4.2
Nozzle diameter (1/100 mm)
50 65 68 81 95
Pre-chamber (printed on nozzle)
-----
Reduced flow rate (W)
450 550 900 900 1400
Rated flow rate G30 (g/h)
80 138 145 218 305
Rated flow rate G31 (g/h)
79 136 143 214 300
9 LPG G30/31 - 50 mbar AUX SR FB R UR2
Rated heating capacity (kW)
1.0 1.8 1.9 3.0 4.1
Nozzle diameter (1/100 mm)
43 58 61 74 80
Pre-chamber (printed on nozzle)
(H2) (M) (Z) (Z) (F4)
Reduced flow rate (W)
400 500 800 800 1500
Rated flow rate G30 (g/h)
73 131 138 218 298
Rated flow rate G31 (g/h)
71 129 136 214 293
10 Town gas G110 – 8 mbar AUX SR FB R UR2
Rated heating capacity (kW)
1.0 1.8 1.9 2.9 3.6
Nozzle diameter (1/100 mm)
145 185 190 260 340
Pre-chamber (printed on nozzle)
/8 /2 /2 /3 -
Reduced flow rate (W)
400 500 800 800 1200