5 Installation
5.1 Clearances above and around domestic appliances
This appliance must be installed by an 
authorised person in accordance with this 
instruction manual, AS/NZS 5601.1 – 
Gas installations (installation and pipe 
sizing), local gas fitting regulations, local 
electrical regulations, Building Code of 
Australia and any other government 
authority.
Requirements
1. Overhead clearances – 
(Measurement A) Range hoods and 
exhaust fans shall be installed in 
accordance with the manufacturer’s 
instructions. However, in no case shall 
the clearance between the highest part 
of the hob of the cooking appliance and 
a range hood be less than 600 mm or, 
for an overhead exhaust fan, 750 mm. 
Any other downward facing combustible 
surface less than 600 mm above the 
highest part of the hob shall be protected 
for the full width and depth of the 
cooking surface area in accordance 
with Clause 5.12.1.2. However, in no 
case shall this clearance to any surface 
be less than 450 mm.
2. Side clearances – (Measurements B & 
C) Where B, measured from the 
periphery of the nearest burner to any 
vertical combustible surface, is less than 
200 mm, the surface shall be protected 
in accordance with Clause 5.12.1.2 to a 
height C of not less than 150 mm above 
the hob for the full dimension (width or 
depth) of the cooking surface area. 
Where the cooking appliance is fitted 
with a ‘splashback’, protection of the 
rear wall is not required.