Instruction manual
Installation
22
Room ventilation
The appliance should be installed in rooms 
that have a permanent air supply in 
accordance with the standards in force. The 
room where the appliance is installed must 
have enough air flow for the regular 
combustion of gas and the necessary air 
change in the room itself. The air vents, 
protected by grilles, must be the right size to 
comply with current regulations and 
positioned so that no part of them is 
obstructed, not even partially.
The room must be kept adequately 
ventilated in order to eliminate the heat and 
humidity produced by cooking: In 
particular, after prolonged use, you are 
recommended to open a window or to 
increase the speed of any fans.
Extraction of the combustion products
The combustion products may be extracted 
by means of hoods connected to a natural 
draught chimney whose efficiency is certain 
or via forced extraction.
An efficient extraction system requires 
precision planning by a specialist qualified 
in this area and must comply with the 
positions and clearances indicated by the 
applicable standards. 
When the job is complete, the installer must 
issue a certificate of conformity.
1 Extraction using a hood
2 Extraction without a hood
A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window-
mounted extractor fan
D Directly outdoors through wall
 Air
 Combustion products
 Extractor fan
5.7 Adaptation to different types of 
gas
If other types of gas are to be used, the 
nozzles must be replaced and the primary 
air must be adjusted. In order to replace the 
nozzles and adjust the burners, the hob top 
must be removed.