2.2  Electrical connection 
Check that the voltage and size of the power supply line are as specified 
on the nameplate inside the storage compartment. 
This nameplate must never be removed. 
The plug on the end of the power supply cable and the wall socket must 
be of the same type (in compliance with the relevant national standards). 
Check that the power supply line is properly earthed. The use of 
reductions, adapters or junctions is not recommended. 
The appliance's power supply line must be fitted with an omnipolar 
breaking device with contact gap of at least 3 mm, located in an easily 
accessible position close to the appliance itself. 
The appliance has a terminal board on 
its rear. 
To access it, remove the back cover. 
Make the electrical connection in 
accordance with the wiring diagram 
shown below. 
Operation at 380-415V3N~: use a H05RR-F 
or H05RN-F five-wire cable (cable of 5 x 1.5 
mm2). 
Operation at 380-415V2N~: use a H05RR-F 
or H05RNF four-wire cable (cable of 4 x 2.5 
mm2). 
Operation at 220-240 V~: use a H05RR-F / 
H05RNF three-wire cable (cable of 3 x 6 
mm2). 
The earth wire (yellow-green) must be at 
least 20 mm longer than the other wires at 
the end for connection to the appliance. 
The manufacturer declines all responsibility for injury or damage 
caused by failure to comply with the above regulations or deriving from 
tampering with even just one part of the appliance. 