Technical data

Instructions for the installer
104
12. ADAPTATION TO DIFFERENT TYPES OF GAS
BEFORE PERFORMING ANY OPERATIONS, SWITCH OFF THE POWER
SUPPLY TO THE APPLIANCE.
Appliance set for gas: NATURAL GAS G20 (2H) 20 mbar pressure
(see label on product)
In case of operation with other types of gas, the burner nozzles must be
changed and the minimum flame adjusted on the gas taps.
To change the nozzles, proceed as described in the following paragraphs.
12.1 Replacing the hob nozzles
1 Remove the pan stands, and remove all burner caps and flame-spreader
crowns to access the burner casings.
2 Unscrew the nozzles using a 7 mm socket wrench.
3 Replace the burner nozzles according to the type of gas to be used (see
12.2 Burner and nozzle characteristics table).
4 Replace the burners in the correct position.