Instruction manual

Installation
41
EN
5.3 Adaptation to different types of
gas
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
cocks.
Replacing nozzles
1. Remove the pan supports, burner caps
and flame-spreader crowns to access
the burner cups.
2. Replace the nozzles using a 7 mm
spanner according to the gas to be used
(see Over time the gas cocks may
become difficult to turn and get blocked.
Clean them internally and replace the
grease.).
1. External injector - 2. Internal injector
3. Replace the burners in their respective
housings.
Adjusting the minimum setting for natural
or town gas
Light the burner and turn it to the minimum
position. Extract the gas cock knob and turn
the adjustment screw next to the gas cock
spindle (depending on the model) until the
correct minimum flame is achieved.
Refit the knob and verify that the burner
flame is stable. Turn the knob rapidly from
the maximum to the minimum setting: The
flame should not go out. Repeat the
operation on all gas cocks.