Operation Manual
Table Of Contents
- 1 Remove the grills and refractory plates (where present) located inside the barbecue compartment.
- 2 Remove the burners from the barbecue compartment detaching them from the fixing pin.
- 3 Using a 7mm socket wrench, unscrew the nozzles positioned on the taps (Change the nozzles according to the table provided above).
- 4 Regulate the air (see primary air adjustment).
- 5 Replace the burners correctly attaching them to the fixing pin.
- 1 Loosen the adjustment screw A of the air regulation sleeve.
- 2 Extract or insert the registration sleeve B to the position that corresponds to the type of gas to be used according to the table below.
- 3 Tighten the adjustment screw making sure that the distance X is correct (See table below).
- 1 Extract the knob.
- 2 Make sure that the by-pass inside is fully screwed in. Use a screw driver inside the tap rod or at the side (See the drawing at the side).
- 3 Turn the by-pass according to the table BURNER, NOZZLE AND GAS CONSUMPTION CHARACTERISTICS
- 4 When the adjustments are completed, insert the knob and light the relative burner bringing it to the minimum position . The flame at minimum should be regular.
- 5 Check the stability of the flame by rapidly turning the knob from the maximum to the minimum position. The flame should not go out.
- 6 If the minimum flame is not regular, remove the knob and move the by-pass with small clockwise or counter-clockwise turns and repeating the flame stability check. If the flame is regular, the minimum adjustment operation has been successful.
- 1 Extract the knob.
- 2 Turn the by-pass inside, screwing it in fully. Use a screw driver inside the tap rod or at the side (See the drawing).

7
Instructions for the installer
INSTRUCTIONS FOR TRANSFORMATION
CONTENTS OF THE PACK
THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE. IT MUST BE KEPT
IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE
WORKING LIFE OF THE PRODUCT. INSTALLATION MUST BE CARRIED OUT
BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN
FORCE. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR
IMPROPER USE.
It contains all the components and the necessary instructions for
converting the barbecue power from GPL gas to METHANE gas.
The appliance is factory set to run on GPL gas; to transform it you must
change the nozzles on all the burners, regulate the primary air and also
regulate the minimum flame on the gas taps.
At the end of these operations, replace the label “regulated for gas” on the
back of the barbecue with the label provided.
THE INSTALLATION MUST BE CARRIED OUT BY A
SPECIALISED TECHNICIAN.
WARNING: Keep the product's standard installation nozzles and the
“regulated for gas” label, since reconversion from METHANE gas to GPL
gas could be necessary in the future.
In the case of reconversion to GPL gas, the conversion procedure is
identical to that described below for METHANE gas.
The contents of the methane gases transformation pack are listed below:
• NOZZLES FOR METHANE GAS.
• LABEL “REGULATED FOR GAS”
(TO BE APPLIED AFTER THE
TRANSFORMATION).