User manual

10
Conversion Kit
1) Broil burner: Open the oven door and remove any accessories that are inside.
2) Unscrew the two fastening screws for the
burner.
3) Remove the burner by sliding it from its
place and reposition it as shown in the
picture. (Make sure not to damage the
thermocouples and the spark electrode).
4) Using a 13mm socket wrench replace the
nozzle, installing the one that is appropriate
for the type of gas to be used. Refer to the
gas charts at point 5.
5) WARNING: The tightening torque of the
nozzle must be equal to 4 Nm - 14.4 Ozf.
Correctly reposition the burner in its place and
screw in the two fastening screws.