Installation
14
2. After having positioned and leveled the
appliance, move the bracket close to the
rear of the appliance and anchor it to the
floor.
3. The bracket attachment should insert into
one of the central slots at the rear.
4. Lower the bracket attachment until
anchoring the appliance slot, tighten the
nuts previously assembled. The anti-tip
device works properly only if the bracket
attachment is securely anchored to the
appliance.
1.5 Electrical requirements
Warning
Electrical shock hazard
• Frame grounded by connection of
grounding lead to neutral lead. If used in
a mobile home or if local codes do not
permit grounding through neutral, open
connection and use grounding lead to
ground unit in accordance with local
codes. Connect neutral lead to branch-
circuit neutral conductor in usual manner.
• Do not use an adaptor.
• Do not use an extension cord.
• Check with a qualified electrician if you
are not sure whether the range is
grounded.
Turn power supply off before connecting
wires.
• Electrically ground the range.
• Failure to follow these instructions can
result in loss of life, fire, or electrical
shock.
• Improperly connecting the appliance
grounding conductor can result in a risk
of electrical shock. Check with a
qualified electrician or serviceman if you
are in doubt as to whether the appliance
is properly grounded. Do not modify the
power supply cord. If it does not fit in the
outlet, have a proper outlet installed by
a qualified electrician.
FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD
RESULT IN LOSS OF LIFE, FIRE
OR ELECTRICAL SHOCK.