User manual
Installation
19
EN
Gas connection
Connect the adapter C (ISO 228/1 -
 ½ NPT) to the gas inlet of the appliance A 
being sure to insert the supplied gasket B.
Apply a suitable sealing substance (such as 
Teflon tape) between pressure regulator D 
and adapter C.
Connect the pressure regulator D to the 
adapter C put on in the previous step (the 
arrow on the back of the regulator points 
towards the gas inlet of the appliance).
Apply a suitable sealing substance (such as 
Teflon tape) between pressure regulator D 
and adapter E (½ NPT - ½ NPT) (not 
supplied). 
Connect the adapter E to the pressure 
regulator D.
Due to problems of overall dimensions at 
the back, screw in the pressure regulator so 
that it is sloped at 45° vs the wall at the 
back of the appliance. 
WARNING: The tightening torque 
of adapter (C / E) must not be 
greater than 36 ozf - 10 Nm.