User manual

Installation
20
Test the appliance
Follow these instructions to leak test the
appliance:
Use a brush and liquid detergent to test all
gas connections for leaks. Bubbles around
connections indicate a leak. If a leak
appears, shut off the gas valve controls and
adjust the connections. Then check the
connections again. Remove all the
detergent product from the range. Replace
the parts on the burner and turn the knobs
on the gas tap valves.
NEVER TEST FOR GAS LEAKS WITH A
MATCH OR OTHER FLAMES.
Shut-off valve
The supply line must be fitted with an
approved shut-off valve.
This valve should be located in the same
room as the range and should be in a
location where it can be easily opened and
closed.
Do not block access to the shut-off valve.
The valve is necessary for turning the gas to
the appliance on or off.
Incoming line pressure
Incoming line pressure upstream from the
regulator must be 1” (2.5 cm) W.C.P. higher
than the manifold pressure in order to check
the regulator. Incoming line pressure to the
regulator should be as follows for operation
and checking the regulator setting:
Natural Gas: Set pressure to 5” W.C.P.
Incoming line pressure of 6” - 10 1/2”
W.C.P maximum.
LP Gas: Set pressure to 10” W.C.P.
Incoming line pressure 11”- 13” W.C.P.
maximum.