9 Burner and nozzle characteristics tables
To adjust the range for LP gas or to return to Natural Gas use, refer to the charts below.
Natural Gas AUX SR RR R DUAL int DUAL est
Oven Broiler
QT (BTU)
4500 8000 10500 12000 4000 16000 17000 17000
Injector Ø (mm)
0.90 1.20 1.40 1.52 0.90 1.75 180 180
QR (BTU)
1200 1600 2400 2400 800 4200 - -
LP AUX SR RR R DUAL int DUAL est
Oven Broiler
QT (BTU)
4200 7500 9500 11000 3500 14500 17000 17000
Injector Ø (mm)
0.60 0.80 0.88 0.98 0.54 1.10 120 120
QR (BTU)
1200 1600 2400 2400 800 4200 - -
By-pass (mm)
0.33 0.39 0.45 0.45 0.30 0.63 - -
NOTE: Save the nozzles that were removed from the appliance along with these
instructions for possible future use.
WARNING
FIRE HAZARD
Use a soapy solution to check that it is leak-tight.
Never test for gas leaks with a match or other flames.
Failure to follow this instruction can result in loss of life or fire.