User manual

Conversion Kit
6
3 Conversion to propane gas (LPG)
Always provide an adequate gas supply.
This appliance is shipped from the factory
for use with natural gas. Use this kit to
convert the appliance for use with propane
gas, if necessary. Comply with the
following: Ensure that the range is
converted for use with the appropriate gas
before using it.
This appliance is designed to operate at a
pressure of 10" of water column when used
with propane gas. When checking if the
regulator is working properly, the inlet
pressure must be at least 1" greater than the
operating (manifold) pressure above.
When converting for propane gas use, the
pressure supplied to the regulator must be
between 11" and 13" of the water column.
The pressure regulator located at the inlet of
the range manifold must remain in the
supply line.
Use a flexible metal appliance connector or
rigid pipe to connect the range to the gas
supply. The connector should have an
inside diameter of 1/2” and be 5 ft (1.5 m)
or less in length.
(Exception: Maximum connector length in
Massachusetts installations is 3 ft (0.9 m). In
Canada, the connector must be single-wall
metal and not longer than 6 ft (1.8 m).
Save the nozzles removed from the
appliance for future use.
WARNING
This conversion kit shall be installed by a
qualified service agency in accordance
with the manufacturer’s instructions and
all applicable codes and requirements of
the authority having jurisdiction. If the
information in these instructions is not
followed exactly, a fire, explosion or
production of carbon monoxide may
result causing property damage,
personal injury or loss of life. The
professional installation service is
responsible for the proper installation of
this kit. The installation is not proper and
complete until the operation of the
converted appliance is checked as
specified in the manufacturer’s
instructions supplied with the kit.
WARNING
A gas leak test should be performed after
the gas conversion has been carried out.
WARNING
Before proceeding with the gas
conversion, the gas supply must be
turned off before disconnecting the
electrical power.