Operation Manual
Instructions for the installer 
38 
7  ADAPTATION TO DIFFERENT TYPES OF GAS 
  Before performing any cleaning or maintenance work, disconnect the 
appliance from the electrical socket. 
The hob has been inspected for G20 (2H) natural gas at a pressure of 
20 mbar. For functioning with other types of gas the nozzles must be 
replaced and the primary air adjusted. 
To replace the nozzles and regulate the burners, you have to remove 
the top as described in the following paragraph. 
7.1  Removing the separable control panel  (models with 
separable control panel) 
1.  Remove the knobs and the knob guard tube “A” by pulling them 
up; 
2.  Use a crosshead screwdriver to remove the screws and the two 
cylindrical supports “B”; 
3.  Raise the left-hand side of the control panel slightly and shift it to 
the right to remove it completely; 
4.  In models with electric hotplate, the body of the pilot light has to be 
removed to free the control panel; 
7.2  Removing the hob (models with integrated control 
panel) 
 1.  Remove the knobs, the griddles, the burner caps, the flame caps 
and the two rear plugs; 
2.  Remove the screws “A” which fix the burner supports; 
Raise the hob, sliding it off the ignition plugs and/or the thermocouples 
and the gas tap rods; 