Contents 1 INSTRUCTIONS FOR SAFETY AND USE __________________________ 28 2 SAFETY PRECAUTIONS _______________________________________ 30 3 ENVIRONMENTAL RESPONSIBILITY _____________________________ 32 4 POSITIONING OF THE HOB ____________________________________ 33 5 ELECTRICAL CONNECTION ____________________________________ 35 6 GAS CONNECTION ___________________________________________ 36 7 ADAPTATION TO DIFFERENT TYPES OF GAS _____________________ 38 8 FINAL OPERATIONS ___________________
General instructions 1 INSTRUCTIONS FOR SAFETY AND USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE. IT MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE HOB. WE ADVISE YOU TO READ THIS MANUAL AND ALL THE INFORMATION IT CONTAINS CAREFULLY BEFORE USING THE HOB. ALSO KEEP THE SERIES OF NOZZLES PROVIDED. INSTALLATION MUST BE CARRIED OUT BY COMPETENT PERSONS IN ACCORDANCE WITH THE REGULATIONS IN FORCE.
General instructions SUITABLE HEAT-PROOF GLOVES SHOULD BE WORN FOR ALL OPERATIONS. DO NOT USE STEEL SPONGES OR SHARP SCRAPERS AS THEY WILL DAMAGE THE SURFACE. USE NORMAL NON-ABRASIVE PRODUCTS AND A WOODEN OR PLASTIC TOOL IF NECESSARY. RINSE THOROUGHLY AND DRY USING A SOFT CLOTH OR A MICROFIBRE CLOTH. DO NOT LEAVE THE APPLIANCE UNATTENDED DURING COOKING PROCESSES WHERE FATS OR OILS COULD BE RELEASED. FATS AND OILS MAY CATCH FIRE.
General instructions 2 SAFETY PRECAUTIONS REFER TO THE INSTALLATION INSTRUCTIONS FOR THE SAFETY REGULATIONS FOR ELECTRIC OR GAS APPLIANCES AND VENTILATION FUNCTIONS. IN YOUR INTERESTS AND FOR YOUR SAFETY THE LAW REQUIRES THAT THE INSTALLATION AND SERVICING OF ALL ELECTRICAL APPLIANCES IS CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. OUR APPROVED INSTALLERS GUARANTEE A SATISFACTORY JOB. GAS OR ELECTRICAL APPLIANCES MUST ALWAYS BE DISCONNECTED BY SUITABLY SKILLED PEOPLE.
General instructions IMMEDIATELY AFTER INSTALLATION, CARRY OUT A QUICK TEST ON THE APPLIANCE FOLLOWING THE INSTRUCTIONS PROVIDED LATER IN THIS MANUAL. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE POWER SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE. NEVER ATTEMPT TO REPAIR THE APPLIANCE. DURING USE THE APPLIANCE BECOMES VERY HOT. BE CAREFUL NOT TO TOUCH THE HEATING ELEMENTS.
Instructions for disposal 3 ENVIRONMENTAL RESPONSIBILITY Our product's packing is made of non-polluting materials, which are therefore compatible with the environment and recyclable. Please help by disposing of the packaging correctly. You can obtain the addresses of collection, recycling and disposal centres from your retailer or from the competent local organisations. Do not discard the packaging or any part of it, or leave it unattended.
Instructions for the installer 4 POSITIONING OF THE HOB The following operation requires building and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long as they are heat resistant (T 90°C). 4.
Instructions for the installer B B 20 ÷ 40 A+B A B B B B Fig.1 Fig.2 A B Fig.3 Fig.4 34 Fig.
Instructions for the installer 5 ELECTRICAL CONNECTION Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded.
Instructions for the installer 6 GAS CONNECTION Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe and conforming to the provisions defined by standard regulations in force. To facilitate connection, fitting A on the rear of the appliance may be adjusted laterally. For this purpose, loosen hexagon nut B, turn fitting A to the desired position, and retighten hexagon nut B (tightness is ensured by a biconical brass ring).
Instructions for the installer 6.1 Connection to LPG Use a pressure regulator and make the connection to the tank according to the provisions of standards regulations in force. Make sure that feed pressure conforms to the levels shown in the table in paragraph “ 0 Regulation for LPG”. 6.2 Ventilation of rooms The hob may be installed only in rooms with permanent ventilation, as required by standards regulations in force.
Instructions for the installer 7 ADAPTATION TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, disconnect the appliance from the electrical socket. The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. For functioning with other types of gas the nozzles must be replaced and the primary air adjusted. To replace the nozzles and regulate the burners, you have to remove the top as described in the following paragraph. 7.1 1. 2. 3. 4. 7.2 1.
Instructions for the installer 7.3 Regulation for LPG Check that the connection has been made as described in the “Gas connection” section. Undo the screw “D” and push the air regulator “C” fully down. Use a spanner to remove the nozzles “B” and fit those of suitable type following the instructions given in the tables for bottled gas G30/G31 – 28/37 mbar. The nozzle must not be tightened to a torque of over 3 Nm.
Instructions for the installer 7.4 Regulation for natural gas The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “ 0 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph “ 7.5 Regulation of primary air”.
Instructions for the installer 7.5 Regulation of primary air Referred to distance “A” in mm. 60 cm hobs with separable control panel. G20 Burner 20 mbar G30/G31 28/37 mbar Auxiliary (1) 3.0 4.0 Semirapid r (2) 1.0 2.0 Semirapid l (3) 1.0 2.0 Rapid large (4) 1.0 3.5 Ultrarapid (5) 1.0 5.0 90 cm hobs with separable control panel. G20 Burner 20 mbar G30/G31 28/37 mbar Auxiliary (1) 2.5 3.0 Semirapid (2) 1.0 2.0 Rapid (3) 1.5 1.5 Fish burner (4) 0.5 8.0 Ultrarapid (5) 1.
Instructions for the installer 8 FINAL OPERATIONS Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “7.1 Removing the separable control panel / 7.2 Removing the hob”. 8.1 Regulation of minimum for natural gas Reposition the components on the burner and slide the knobs onto the cock stems. Light the burner and set it on the minimum position.
Instructions for the installer 8.3 Arrangement of the burners on the hob (Hob with separable control panel) 60 cm. hob BURNERS 1. 2. 3. 4. 5. Auxiliary Semirapid r Semirapid l Rapid large Ultrarapid 90 cm. hob BURNERS 1. 2. 3. 4. 5.
Instructions for the installer 8.4 Arrangement of the burners on the hob (Hob with built-in control panel). 60 cm. hob BURNERS 1. 2. 3. 4. 5. 8.5 Auxiliary Semirapid r Semirapid l Rapid Ultrarapid Lubrication of gas taps With time it may happen that the gas taps get blocked and hard to turn. Clean them inside and re-grease them. This operation must be done by an authorised person.
Instructions for the user 9 USING THE HOB Before turning on the burners, make sure that the burner rings, caps and grids have been fitted correctly. In the ultrarapid burner, notch A must be aligned with pin B. Grid C provided is intended for use with woks (Chinese pans). Adapter D comes only with open grids models and is intended for use with small sized vessels. 9.1 Ignition of the burners The device is fit with electronic ignition.
Instructions for the user while cooking, all pans or griddles must be positioned within the cooking hob perimeter and must be a minimum distance of 3-4 cm from the knobs. 9.3 Diameter of the pans Burners Ø min. and max. (en cm.) Auxiliary 12-14 Semirapid 16-20 Rapid medio 22-26 Rapid large 22-26 Ultrarapid 22-26 Fish burner 9.4 Special oval-shaped vessels Electric elements 9.4.1 Turning on electric elements Hobs may be fitted with an electric element of varying diameter.
Instructions for the user or fish. 5 Strong For roasts, steaks and large boiled joints. 6 Very strong To boil large amounts of water, to fry. WARNING When switching on the electric element for the first time, or if the electric element has not been used for a long time, to remove any humidity from the insulating material it should be dried out by placing the electric element on position 1 for 30 minutes.
Instructions for the user 10 CLEANING AND MAINTENANCE Never use a steam jet to clean the appliance. Before any intervention, disconnect the power supply of the device. 10.1 Cleaning Clean the cooking top regularly every time you use it, obviously after it has cooled. 10.1.1 Regular daily cleaning of the hob In order to clean and preserve the surface, always use specific products only, which do not contain abrasive substances or chlorinebased acid substances.
Instructions for the user 10.2 Cleaning of cooking hob components CAUTION: do not wash these components in a dishwasher. In normal use of the hob, the stainless steel burner caps and panstands tend to be burnished by the high temperature. Clean these parts using very fine abrasive sponges or similar commercial products. Then use a specific paste polish to restore the steel’s shine. Your local authorised after-sales technician is able to supply professional products for appliance cleaning and care.