Operation Manual

Instructions for the installer
33
5.3 Regulation for LPG
Check that the connection has been made as described in the “Gas
connection” section.
Undo the screw “D” and push the air regulator “C” fully down. Use a
spanner to remove the nozzles “B” and fit those of suitable type
following the instructions given in the tables for bottled gas G30/G31 –
28/37 mbar. The nozzle must not be tightened to a torque of over 3 Nm.
Regulate the air flow by moving the Venturi pipe “C”, until the gap “A” is
as shown in the table in point “5.5 Regulation of primary air” and fix it
with the screw “D”. After making the adjustments, restore the seals
with sealing wax or an equivalent material.
Burner
Rated
heating
capacity
LPG – G30/G31 28/37 mbar
Nozzle
Diameter
1/100
mm
By-pass
1/100
mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.05 48 30 360 76 75
Semi-rapid 1.7 62 30 360 124 121
Rapid 2.55 76 40 650 185 182
Rapid large 3.1 85 45 800 225 222
Fish pan 2.9 82 50 950 211 207
Ultra rapid 4.0 95 65 1600 291 286