5.3  Regulation for LPG 
   Check that the connection has been made as described in the “Gas 
connection” section. 
Undo the screw “D” and push the air regulator “C” fully down. Use a 
spanner to remove the nozzles “B” and fit those of suitable type 
following the instructions given in the tables for bottled gas G30/G31 –
28/37 mbar. The nozzle must not be tightened to a torque of over 3 Nm. 
Regulate the air flow by moving the Venturi pipe “C”, until the gap “A” is 
as shown in the table in point “5.5 Regulation of primary air” and fix it 
with the screw “D”. After making the adjustments, restore the seals 
with sealing wax or an equivalent material. 
Burner 
Rated 
heating 
capacity 
LPG – G30/G31 28/37 mbar 
Nozzle 
Diameter
1/100 
mm 
By-pass 
1/100 
mm 
Reduced
flowrate 
(W) 
Flowrate 
g/h G30 
Flowrate 
g/h G31 
Auxiliary  1.05  48  30  360  76  75 
Semi-rapid  1.7  62  30  360  124  121 
Rapid  2.55  76  40  650  185  182 
Rapid large  3.1  85  45  800  225  222 
Fish pan  2.9  82  50  950  211  207 
Ultra rapid  4.0  95  65  1600  291  286 