Operation Manual
Instructions for the installer 
35 
5.5  Regulation of primary air 
Referred to distance “A” in mm. 
60 cm hobs with separable control panel. 
Burner 
G20 
20 mbar 
G30/G31 
28/37 mbar 
Auxiliary (1)  3.0  2.5 
Semirapid r (2)  1.0  2.0 
Semirapid l (3)  1.0  1.5 
Rapid large (4)  1.0  2.5 
  Ultrarapid (5)  1.5  4.0 
   90 cm hobs with separable control panel. 
Burner 
G20 
20 mbar 
G30/G31 
28/37 mbar 
Auxiliary (1)  2.5  2.5 
Semirapid (2)  1.0  2.0 
Rapid (3)  1.5  1.5 
Fish burner (4)  0.5  8.0 
Ultrarapid (5)  1.5  5.5 
60 cm hob with built-in control panel. 
Burner 
G20 
20 mbar 
G30/G31 
28/37 mbar 
Auxiliary (1)  3.0  2.5 
Semirapid r (2)  1.0  2.5 
  Semirapid l (3)  1.0  2.0 
  Rapid medio (4)  1.0  2.5 
  Ultrarapid (5)  1.0  3.0 