User manual
EN 
4 
INSTALLATION INSTRUCTIONS: 
The hood is supplied with all the necessary 
accessories  for  installation.  The  minimum  distance 
between the cooker and the lower part of the hood 
must  be  750  mm  for  gas  cookers  and  650  mm  for 
electric cookers (Fig.1). The hood is supplied with a 
motor intake (Fig 2). If it has not been assembled by 
the manufacturer, you can assemble it using the 
supplied screws (for type 1) or pushing (for type 2) 
If the motor intake is equipped with a non-return 
valve, make sure it opens and closes perfectly. 
The following instructions will assist installation: 
a) The hood should be centred with respect to the 
 cooker. 
b) The hood is supplied with two supports/hooks (a) 
 (Fig 3) or bracket (b) that need to be fixed to the 
 wall by means of wall anchors . The L1 holes for 
 these supports are on the back of the hood (fig.4) 
c) Remove the anti-grease filters, put the hood on 
 the wall and mark the position of the holes for the 
 supports/hooks. 
d) Drill the two previously marked holes after 
 removing the hood from the wall. 
e) Fix the two supports/hooks to the wall. 
f) Mark the L2 holes on the wall to fix the hood 
 safely. (fig. 4) Drill and put the anchors in the 
 holes. 
g) Hang the hood on to the supports/hooks (fig. 5) 
and level by means of the adjusting screw 
(fig.3). 
l) Fix the hood safe by tightening both wall anchors. 
Ducted mode or Recirculation mode installation: 
Ducted mode: 
In the ducted mode, connect the motor outlet to the 
fumes outlet duct not less than 120mm diameter. 
Warning: if the hood is equipped with an active 
carbon filter, it must be removed (see page7) 