Dear Customer, If you follow the recommendations contained in this Instruction Manual, your appliance will give you constant high performance and will remain efficient for many years to come.
RECOMMENDATIONS AND SUGGESTIONS INSTALLATION • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. • The minimum safety distance between the cooker top and the extractor hood is 650 mm. • Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood. • For Class 1a appliances, check that the domestic power supply guarantees adequate earthing.
CHARACTERISTICS Dimensions 0 8 20 174 Ø 119 4 28 L1 Hood Type L1 52 522 70 702 Components Ref. 1 Q.ty Product Components 1 Hood Body, complete with: Controls, Light, Filters Q.
INSTALLATION Drilling the Support surface and Fitting the Hood Make a rectangular opening on the base of the hanging unit, leaving a minimum of 13 mm from the outer edges. Hood Type L1 52 497 70 677 259 13 L1 SNAP-ON FITTING For hoods with snap-on side supports only, set up for a support panel thickness of between 15 mm and 30 mm. • Insert the hood until the side supports snap into place. • Lock in position by tightening the screws Vf from underneath the hood.
Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 120 mm. ø 120 • Fix the pipe in position using sufficient pipe clamps (not supplied). • Remove any activated charcoal filters. 9 RECIRCULATION VERSION AIR OUTLET • Cut a hole ø 120 mm in the wall unit over the hood. • Connect the hood body outlet to the top part of the wall unit using a rigid or flexible pipe ø 120 mm, to be selected by the installer.
USE Control Panel L Light Switches the lighting system on and off. M Motor Switches the extractor motor on and off. V Speed Sets the operating speed of the extractor.
MAINTENANCE Grease filters CLEANING METAL SELF-SUPPORTING GREASE FILTERS • The filters must be cleaned every two months of operation, or more frequently with heavy usage. • Remove the filters one at a time, after disconnecting the relative fastening elements. • Wash the filters, taking care not to bend them. Allow them to dry before refitting. • When refitting the filters, make sure that the handle is visible on the outside.
Quest’apparecchio è conforme alla norma europea sulla bassa tensione C.E.E. 73/23 relativa alla sicurezza elettrica e alle norme europee: C.E.E. 89/336 relativa alla compatibilità elettromagnetica e C.E.E. 93/68 relativa alla marcatura CE. This appliance conforms to European Low Voltage Directive 73/23/CEE governing electrical safety, European Directive 89/336/ CEE on Electromagnetic Compatibility and Directive 93/68/CEE regarding CE Marking.